Fig. 10 Recommended machine placement and dimensions [mm]
A
Exhaust fan
Z
Air inlet aperture
CAUTION
Ambient temperature too low.
The reduced lubrication properties of oil that is too viscous can result in damage when starting the
machine.
➤ Ensure that the temperature of the machine is at least +3 ℃ before starting.
➤ Make sure the compressor room is adequately heated.
1. If installed outdoors, the machine must be protected from frost, direct sunlight, dust and rain.
2. Ensure adequate lighting so that all work on the machine can be carried out without danger or
hindrance.
5.2.2 Ensuring adequate ventilation
If the ventilation is insufficient, a partial vacuum can be created in the room.
1. Ensure that the volume of air flowing into the machine room is at least equivalent to that being
removed from it by the machine and exhaust fan.
2. Make sure that the machine and exhaust fan can only operate when the inlet aperture is actually
open.
3. Keep the inlet and exhaust apertures free of obstructions so that the cooling air can flow freely
through the room.
Further information See chapter 2.6 for ventilation aperture dimensions.
5
Installation and Operating Conditions
5.2
Installation conditions