➤ When operating conditions are unfavourable (e.g. dusty or humid atmosphere) or when the
equipment is in constant use, have the service work carried out more frequently (shorter intervals).
Interval
Service task
Every 2 years at least
Change the air filter element
Up to 3000 h
Have cylinder head and valves checked.
Up to 12,000 h
Have the machine generally overhauled.
up to 12,000 h, every three
years at the latest
Have motor bearings checked.
up to 36,000 h, every six
years at the latest
Replace prepared hoses
h = operating hours
Tab. 38 Regular service tasks
10.3 Maintaining the air cooler or fan guard
According to machine model, it either has an air cooler of a fan guard.
Clogging causes overheating and machine damage.
Regular cleaning ensures reliable cooling of the machine and the compressed air. The frequency is
mainly dependent on local operating conditions.
Material Brush
Vacuum cleaner
Face mask (as required)
Precondition The supply disconnecting device is switched off,
the device is locked off,
a check has been made that no voltage is present.
The machine has cooled down.
Fig. 21 Cleaning the air cooler or fan guard
1
Compressed air cooler
2
Fan with guard
3
Brush
10 Maintenance
10.3 Maintaining the air cooler or fan guard
52
Assembly and operating manual 2-stage piston compressor
EPC-2-G
No.: 9_5753_04 E