6. Position the cover over the insert and close the retaining clips.
7. Mount the air filter again.
The filter air inlet must face downwards.
8. Switch on the power supply disconnecting device.
10.5 Option H9
Air filter (noise absorbing) maintenance
Check that all sealing surfaces match each other. The use of an unsuitable air filter element can
permit dirt to ingress the pressure system and cause damage to the machine.
Material Compressed air for blowing out
Spares as required
Precondition The supply disconnecting device is switched off,
the device is locked off,
a check has been made that no voltage is present.
The machine has cooled down.
Fig. 23 Air Filter (noise absorbing) Maintenance
1
Air filter element
2
Inlet air opening
3
Retaining clip
4
Cover
10 Maintenance
10.5 Air filter (noise absorbing) maintenance
54
Assembly and operating manual 2-stage piston compressor
EPC-2-G
No.: 9_5753_04 E