System
6000
TM
Reference
Manual_Section
3
3.2
Keycard
Levels
(continued)
Special
Lock
Levels
Secondary
Program
Keycard
(SPK)
This
keycard
is
used
to
reprogram
the
current
Primary
Program
keycard
(PPK)
or
remaster
a
different
PPK
into
a
lock.
This
card
should
only
be
made
at
the
direction
of
SAFLOK
service
personnel.
Primary
Program
Keycard
(PPK)
This
keycard
is
a
non
‐
opening
keycard
that
is
used
in
conjunction
with
Program
Information
(PI)
keycards
and
Program
Status
(PS)
keycards
for
programming
locks
and
for
performing
special
functions.
It
is
also
used
to
reprogram
the
current
SPK
or
remaster
a
different
SPK
into
a
lock.
Sub
Functions
within
Keycard
Groups
Unlatch/Latch
Alternately
leaves
the
lock
unlatched
or
latched.
When
a
lock
is
unlatched,
no
keys
are
necessary.
This
level
operates
a
lock
or
a
group
of
locks.
Pass
The
room/unit,
section,
floor,
and
Grand
Master
levels
can
be
programmed
as
pass
levels
to
allow
all
the
keys
from
the
level
to
operate
the
lock.
Selectable
A
keycard
can
be
assigned
to
have
access
to
special
areas
during
the
encoding
process.
An
example
might
be
giving
the
keycard
access
to
the
parking
garage
or
health
club
if
the
property
charges
for
using
these
facilities.
Up
to
six
different
selectable
pass
areas
can
be
assigned
in
the
system.
Shift
Times
Master
‐
level
keycards
can
be
programmed
to
work
only
during
certain
hours
of
the
day.
When
the
keycard
is
made,
the
user
can
select
the
start
and
end
times
of
the
shift.
A
keycard
can
only
have
one
specified
shift
time.
If
the
keycard
is
used
outside
of
the
shift
time,
it
will
not
work.
Auto
Unlatch/Latch
A
lock
can
be
programmed
to
automatically
unlatch
and
latch
at
specified
times
each
day.
Indicate
the
unlatch/latch
times
and
the
day
of
the
week
with
the
lock
name
(e.g.,
pool,
Sunday
through
Thursday,
unlatch
at
9
a.m.
and
latch
at
10
p.m.;
Friday
and
Saturday,
9
a.m.
and
latch
at
12
a.m.).
Memory
Keycards
/
RFID
Keycards
or
FOB’s
Stores
information
to
track
employees.
When
a
memory
keycard
is
used
in
a
lock,
it
records
the
room
number,
date,
and
time
of
day.
In
addition,
a
memory
card
can
be
used
to
interrogate
a
lock.
Locks
must
have
software
version
12.15.03
or
greater
for
interrogation
with
a
memory
card.
© SAFLOK
Page
4
of
24
06/11
Содержание Saflok SYSTEM 6000
Страница 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Страница 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Страница 4: ...Section 1 Introduction to System 6000 ...
Страница 9: ...SECTION 2 System 6000 Installation and Configuration ...
Страница 35: ...SECTION 3 Lock and Keycard Features ...
Страница 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Страница 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Страница 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...