Code
Description
177
PI
Keys:
The
PPK
or
SPK
key
used
to
start
the
program
cycle
was
not
authorized
to
program
this
PI
key
into
the
lock.
Use
a
PPK
or
SPK
with
the
proper
authorization.
Refer
to
Section
5.
178
Standard
Key:
The
key
is
new
and
is
identified
as
a
pre
‐
reg
key
which
will
not
work
until
its
check
‐
in
date
and
time.
If
desired,
replace
key
with
a
new
key.
179
Display
Key:
Key
has
an
invalid
function
(greater
than
3).
Contact
SAFLOK
for
assistance.
180
LPI
Request:
Key
appears
to
be
an
LPI
request
but
lock
is
not
in
LPI
mode.
Contact
SAFLOK
for
assistance.
181
LPI
Request:
Key
has
an
invalid
LPI
function
(not
equal
to
0
‐
7
or
128
‐
131).
Contact
SAFLOK
for
assistance.
182
PI
Basic:
PI
key
must
program
in
the
hardware
and
communication
mode
when
the
lock
is
in
Mode
1
Formatted
and
Unprogrammed.
Contact
SAFLOK
for
assistance.
183
Standard
Key:
When
the
lock
is
in
the
LPI
mode,
the
lock
will
not
allow
the
door
to
be
opened
(opening
key)
unless
the
lock’s
batteries
are
low,
the
lock
is
in
Mode
3
Override
or
the
lock
is
in
Mode
5
Critical
Locking
Problem.
Contact
SAFLOK
for
assistance.
184
PPK
Key:
The
key
is
new
but
the
lock
is
in
Mode
4
E2
Disabled
and
new
keys
are
not
accepted.
Contact
SAFLOK
for
assistance.
185
Display
Key:
When
the
lock
is
in
the
LPI
mode,
the
lock
will
not
accept
Display
keys
since
the
LPI
cannot
read
them.
Contact
SAFLOK
for
assistance.
186
Standard
Key:
The
key
is
accepted,
but
is
non
‐
opening
and
will
not
open
the
door.
187
Status
Key:
In
a
programming
cycle,
the
Status
key
was
used
after
PI
keys,
but
it
must
be
the
first
and
only
key
after
the
program
cycle
begins.
To
program
in
a
Status
Key,
use
the
PPK
or
SPK
key
followed
by
the
Status
key.
188
All
Keys:
The
lock
is
in
Test
Mode
indicating
fatal
problem
occurred
and
the
lock
should
be
returned
to
supplier.
Only
LPI
interrogations
are
allowed.
The
lock
must
be
drilled
to
access
the
room.
189
Standard
Key:
The
key
is
an
opening
key
but
the
lock
found
the
hardware
switches
indicated
a
motor
might
be
connected
even
though
the
lock’s
hardware
mode
indicates
a
solenoid
is
connected.
Opening
keys
will
not
be
accepted
until
the
lock’s
hardware
mode
is
programmed
to
match
the
switch
indications.
Contact
SAFLOK
for
assistance
190
Status
Key:
LED
Diagnostics
Key.
The
LED
Diagnostics
key
did
not
do
anything.
If
you
were
trying
to
turn
LED
Diagnostics
on,
you
must
use
the
PPK
key
first.
If
you
were
trying
to
turn
LED
Diagnostics
off,
no
further
action
is
required
since
LED
Diagnostics
is
already
off.
Содержание Saflok SYSTEM 6000
Страница 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Страница 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Страница 4: ...Section 1 Introduction to System 6000 ...
Страница 9: ...SECTION 2 System 6000 Installation and Configuration ...
Страница 35: ...SECTION 3 Lock and Keycard Features ...
Страница 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Страница 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Страница 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...