Code
Description
205
Unauthorized
access
error.
Re
‐
encode
key
as
a
duplicate
key
and
test
in
lock.
Contact
SAFLOK
for
further
assistance
if
needed.
206
Errors
generated
by
smartcard
chip.
Test
the
key
in
another
lock
to
verify
the
key
is
not
damaged.
Contact
SAFLOK
for
further
assistance
if
needed.
212
key
is
the
current
sequence
(not
new)
and
the
key's
ID
has
been
canceled.
Must
issue
new
duplicate
key
or
new
sequence
key.
213
The
lock
does
not
keep
track
of
canceled
IDs
for
the
keys
for
this
level.
Contact
SAFLOK
for
further
assistance
if
needed.
214
Cancel
key's
new
key
date
or
Sequence
is
newer
than
that
in
the
lock
for
the
key
records
and
the
key
can
be
auto
‐
inhibited
or
its
new
sequence
expiration
is
based
on
when
the
new
sequence
is
first
used.
(can't
accept
new
key
data
in
this
circumstance
because
new
sequence
will
be
inhibited
or
expired).
Contact
SAFLOK
for
further
assistance
if
needed.
215
Key
ID
is
already
cancelled:
This
Cancel
‐
a
‐
key
‐
ID
key
will
not
cancel
this
key.
Contact
SAFLOK
for
further
assistance
if
needed.
216
There
was
not
enough
space
to
add
the
variable
key.
Contact
SAFLOK
for
further
assistance
if
needed.
217
The
interrogation
memory
card
already
has
an
interrogation
on
it.
Save
the
records
stored
on
the
key
and
re
‐
encode
as
an
interrogation
key.
Contact
SAFLOK
for
further
assistance
if
needed.
220
This
particular
change
key
is
already
in
random
list.
Contact
SAFLOK
for
further
assistance
if
needed.
221
The
requested
change
key
to
add
is
already
being
used
as
a
variable
key.
Contact
SAFLOK
for
further
assistance
if
needed.
Содержание Saflok SYSTEM 6000
Страница 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Страница 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Страница 4: ...Section 1 Introduction to System 6000 ...
Страница 9: ...SECTION 2 System 6000 Installation and Configuration ...
Страница 35: ...SECTION 3 Lock and Keycard Features ...
Страница 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Страница 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Страница 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...