Code
Description
150
Special
Key:
Key
is
current
but
key
is
inhibited.
Replace
key
with
a
new
key.
151
Standard
Key:
Key
is
an
old
key
–
lock
level
is
batch
and
key’s
sequence
number
has
already
been
used.
Replace
key
with
an
unused
sequence.
152
Standard
Key:
Key’s
level
is
electronically
locked
out.
If
this
key
is
a
dual,
electronic
lock/unlock,
inhibit
level,
or
unlatch/latch
key;
it
will
not
perform
its
function.
The
electronic
unlock
key
must
be
used
to
remove
the
electronic
lockout.
153
Standard
Key:
Key
is
non
‐
opening
and
lock
is
in
Mode
3
Override.
Use
an
opening
key
or
a
different
master
level
key.
154
Standard
Key:
Key
is
an
opening
key,
but
the
lock
is
dead
bolted
and
the
key
cannot
override
it.
155
Standard
Key:
Lock
was
in
Dual
key
cycle
and
the
same
dual
key
was
used
twice
in
a
row.
Use
a
different
dual
key
after
using
the
first
dual
key.
156
Standard
Key:
Lock
was
in
Dual
key
cycle
and
both
dual
keys
were
non
‐
control
(non
‐
opening)
keys.
Use
at
least
one
control
(opening)
dual
key.
157
Standard
Key:
Opening
key,
low
battery
lockout.
Lock
level
for
this
key
is
locked
out
when
a
low
battery
condition
exists;
this
key
did
not
perform
any
special
function
and
was
not
allowed
to
open
the
door.
Use
another
master
level
key
to
open
the
door
and
replace
the
batteries.
158
Standard
Key:
Opening
key,
low
battery
lockout.
Lock
level
for
this
key
is
locked
out
when
a
low
battery
condition
exists.
This
key
did
perform
a
special
function
(inhibit
levels
or
electronic
lock)
but
was
not
allowed
to
open
the
door.
Use
another
master
level
key
to
open
the
door
and
replace
the
batteries.
159
Standard
Key:
Opening
key,
clock
reset
lockout.
Lock
level
for
this
key
is
locked
out
when
the
lock’s
clock
needs
resetting.
This
key
did
not
perform
any
special
function
and
was
not
allowed
to
open
the
door.
Use
another
master
key
to
open
the
door
and
reset
the
lock’s
clock.
160
Standard
Key:
Opening
key,
clock
reset
lockout.
Lock
level
for
this
key
is
locked
out
when
the
lock’s
clock
needs
resetting;
this
key
did
perform
a
special
function
(inhibit
levels
or
electronic
lock)
but
was
not
allowed
to
open
the
door.
Use
another
master
key
to
open
the
door
and
reset
the
lock’s
clock.
161
Standard
Key:
Opening
key,
low
battery
hassle.
Lock
level
for
this
key
is
hassled
when
a
low
battery
condition
exists;
this
key
did
not
perform
any
special
function
and
was
not
allow
to
open
the
door.
Use
the
key
again
to
open
the
door.
Replace
the
batteries.
162
Standard
Key:
Opening
key,
low
battery
hassle.
Lock
level
for
this
key
is
hassled
when
a
low
battery
condition
exists;
this
key
did
perform
a
special
function
(inhibit
levels
or
electronic
lock)
but
was
not
allowed
to
open
the
door.
Use
the
key
again
to
open
the
door
and
replace
the
batteries.
PI
Basic
Errors
in
Program
Cycle
continued
Содержание Saflok SYSTEM 6000
Страница 1: ...REFERENCE MANUAL SYSTEM 6000 ...
Страница 2: ...SAFLOK TRAINING AND REFERENCE MANUAL SAFLOK SYSTEM 6000 WINDOWS VERSION 3 ...
Страница 4: ...Section 1 Introduction to System 6000 ...
Страница 9: ...SECTION 2 System 6000 Installation and Configuration ...
Страница 35: ...SECTION 3 Lock and Keycard Features ...
Страница 59: ...System 6000 TM Reference Manual_Section 4 Section 4 Lock Operation SAFLOK Page 1 of 16 06_11 ...
Страница 75: ...System 6000 TM Reference Manual_Section 5 Section 5 System 6000 Transactions ...
Страница 99: ...System 6000 TM Reference Manual_Section 6 Section 6 Diagnostics Error Codes ...