Move the engine 3 start switch to
START
to begin the start sequence for that engine.
The starter light will illuminate to indicate that the starter system is energised.
The IGN 1 light will illuminate, shortly followed by the IGN 2 light, indicating that both ignitors are charged.
Engine 3 should begin to spool up. The LP shaft rotation light will illuminate once engine 3 LP rotation has
begun. This can be monitored on the engine instruments located above the engine start panel.
Once engine 3 has reached idle speed (approximately 28% HP RPM), return the engine 3 start switch to the
OFF
position.
Disconnect the ground air supply and then repeat the process to start engine 4, 2 and then 1.
With all the engines started, rotate the start master selector knob back to the
ALL OFF
position and close the
plastic cover. All the indicator lights on the panel should extinguish.