VC10 Professional – Operations Manual
36
Flight Engineer’s station – upper electrical panel
The electric panel is situated below the PFCU panel, in the centre of the Engineer’s panel. For clarity it is spilt
into two sections. The largest subpanel is used for controlling the AC power supply on board the VC10, which is
provided by generators found within each engine. You can trip the faulty generators or disconnect its drive from
the engine.
1. No.1 generator bus-tie magnetic indicator
2. Split-system breaker (SSB) control switch
3. Split-system breaker (SSB) magnetic indicator
4. No.2 generator bus-tie magnetic indicator
5. Frequency control rheostats
6. Generator control switches
7. Generator circuit breaker magnetic indicators
8. Generator KW/KVAR meters
9. Generator control relay switches
10. Low oil pressure warning lights
11. CSD oil outlet/generator stator temperature gauges
12. Generator drive disconnect switches
13. Generator failure warning lights
14. ELRAT light (non-functional in this simulation)
15. No.3 busbar/auxiliary/ELRAT busbar magnetic indicator
16. No.4 generator bus-tie magnetic indicator
17. AC frequency meter
18. No.3 generator bus-tie magnetic indicator