48–VDC facility DC source should be equipped with a circuit breaker rated at 5 A @–48 VDC
minimum, or as required by local code.
For other nominal input voltages such as 24 VDC, –60 VDC, we recommend that the circuit
breaker rating be appropriately sized or rated, and as required by local code.
6. Tighten the power cord plug screw.
The power cord plug screw prevents water and dust from entering the terminal.
7. Verify that the power cabling is correct, that the power cables do not touch or block access to router
components, and that they do not drape where people could trip on them.
8. Observe the system LED on the router. If an DC power supply is functioning normally, the system
LED lights green steadily.
If the system LED is not lit, the power supply is not functioning normally. Repeat the cabling
procedures.