61
12 IO-Link data
a
RW = Read and write access
RO = Read access only
WO = Write access only
Sensor stress
Designation
Index Sub-
index
Data type
Value range
Default Ac-
cess
right
a
a
RW = Read and write access
RO = Read access only
WO = Write access only
Description
Alarm activation
300
0
TENUM
TENUM values:
0x00: Inactive
0x01: Active
0x00
RW
d = days
CIP/SIP cycle acquisition
Designation
Index Sub-
index
Data type
Value range
Default Ac-
cess
right
a
a
RW = Read and write access
RO = Read access only
WO = Write access only
Description
CIP temperature
320
0
TFLOAT
-20 to 150 °C
80
RW
CIP cycle dura-
tion
321
0
TUINT16
0 to 65535 s
1800
RW
SIP temperature
322
0
TFLOAT
-20 to 150 °C
121
RW
SIP cycle dura-
tion
323
0
TUINT16
0 to 65535 s
1800
RW
Alarming
324
0
TENUM
TENUM values:
0x00: Active
0x01: Inactive
0x01
RW
Max. number of
CIP cycles alarm
325
0
TUINT16
0 to 999
50
RW
Max. number of
SIP cycles alarm
326
0
TUINT16
0 to 999
50
RW
Max. number of
CIP cycles pre-
alarm
327
0
TUINT16
0 to 999
45
RW
Max. number of
SIP cycles pre-
alarm
328
0
TUINT16
0 to 999
45
RW
Содержание digiLine CR HT10
Страница 2: ......
Страница 6: ...Contents...
Страница 16: ...3 Device Description 16...
Страница 26: ...4 Identifying the device version 26...
Страница 50: ...10 Troubleshooting in the event of faults 50...
Страница 70: ...12 IO Link data 70...
Страница 78: ...14 Operation maintenance and care 78...
Страница 83: ......