12
10. Replace the burner tube, BE SURE TO SLIDE TUBE TO
THE LEFT COMPLETELY COVERING ORIFICE.
11. Open the bottom grill assembly to access the valve.
12. Change the variable regulator on the valve (Hi/Lo
knob). Using a Torx t-20 screwdriver or small flat
head screwdriver, remove the three specialty screws
from the front of the valve regulator. See fig. 10.
13. Remove the regulator tower and gasket.
B
B
B
B
BE SU
E SU
E SU
E SU
E SUR
R
R
R
RE
E
E
E
E T
TT
T
TO R
O R
O R
O R
O REM
EM
EM
EM
EMO
O
O
O
OVE
VE
VE
VE
VE T
TT
T
TH
H
H
H
HE B
E B
E B
E B
E BLLLLLA
A
A
A
AC
C
C
C
CK RU
K RU
K RU
K RU
K RUB
B
B
B
BB
B
B
B
BER G
ER G
ER G
ER G
ER GA
A
A
A
ASKET
SKET
SKET
SKET
SKET
FR
FR
FR
FR
FRO
O
O
O
OM
M
M
M
M T
TT
T
TH
H
H
H
HE
E
E
E
E V
V
V
V
VAL
AL
AL
AL
ALVE.
VE.
VE.
VE.
VE. See fig. 10.
14. Install the new variable regulator tower with the
new rubber gasket. Thor
Thor
Thor
Thor
Thoroughly
oughly
oughly
oughly
oughly tighten new regula-
tor to valve body.
15. Install the identification labels to the insert so that
they can be seen by any person that may be servicing
the insert. APPLY LABEL B TO THE RATING PLATE IN
THE SPACEPROVIDED.
16. Reassemble the insert, apply gas to the system and
check for gas leaks including all insert lines before
and after the valve.
N
N
N
N
NE
EE
EEVER USE AN OPEN FL
VER USE AN OPEN FL
VER USE AN OPEN FL
VER USE AN OPEN FL
VER USE AN OPEN FLA
A
A
A
AME
ME
ME
ME
ME T
TT
T
TO C
O C
O C
O C
O CH
H
H
H
HEC
EC
EC
EC
ECK F
K F
K F
K F
K FOR G
OR G
OR G
OR G
OR GA
A
A
A
AS
SS
SS
LE
LE
LE
LE
LEAK
AK
AK
AK
AKS
SS
SS.....
IMP
IMP
IMP
IMP
IMPOR
OR
OR
OR
ORT
TT
T
TAN
AN
AN
AN
ANT
TT
T
T
Correct gas pressure is essential for efficient and safe
operation of the Katahdin gas insert. It is important
that the correct gas pressure be established at the time
of the installation. For more details, see the Gas Pres-
sure section of this manual on page 14.
ALWAYS REFER TO THE LIGHTING INSTRUCTIONS ON THE
BACK COVER OF THIS MANUAL WHEN LIGHTING YOUR
KATAHDIN.
Gas Supply Connection
The gas supply line connection is made to the valve on
the left side of the unit facing the front. The gas supply
line should be a minimum of 3/8" in diameter, or the
appropriate size to provide sufficient gas pressure to the
valve regardless of the input setting.
See fig. 11 and 12.
For your convience the GI 450 DV Katahdin is
shipped with a short piece of 3/8” iron and a 24” length
of flexible gas line. Jotul recommends the use of the
flexible gas line for ease of installation and service.
However, for those areas where flexible gas lines are not
permitted use of the 3/8” iron is recommended. See fig.
12.
The use of Flexible Gas Appliance Connectors is
acceptable in many areas in the U.S., however, Canadian
methods vary depending on local code.
ALL INSTALLATIONS MUST COMPLY WITH LOCAL
CODE OR IN THE ABSENCE OF LOCAL CODE, MUST
COMPLY WITH THE MOST RECENT EDITION OF THE
NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR
CAN-B149.
All codes require: a gas shut-off valve (gas cock) .union,
to be installed in the supply line, and in the same room as
the appliance. This allows for the disconnection of the
insert for servicing and maintenance. See fig. 12.
T-handle gas cocks are required in
Massachusetts in compliance with
code 248CMR.
BE SURE TO REMOVE THE
BLACK RUBBER GASKET
FROM THE VALVE.
Figure 10.
Regulator Assembly.
Pilot Hood
Pilot
orifice
screws
into base
Figure 9. Pilot Assembly.
Pilot
Orifice