13
Secure all joints tightly using appropriate tools and
sealing compounds (for propane units, be sure to use
compounds that are propane resistant). Turn on gas
supply and test for gas leaks using a soapy water
solution. Never use an open flame to check for leaks.
LLLLLeak
eak
eak
eak
eak T
TT
T
Test:
est:
est:
est:
est:
····· Mix a 50-50 solution of water and dish soap.
····· Light appliance - See lighting instructions on page 23
of this manual or on the rating plate.
····· Brush or spray all joints and connections with the
soapy water solution.
····· If bubbles appear at any connection or seam or a gas
odor is detected, immediately turn gas control knob
to the OFF position.
Tighten or reconnect the leaking joint and retest for any
gas leaks.
Gas Pressures
Correct gas pressure is essential for efficient and safe
operation of the Katahdin gas insert. It is important that
the correct pressure is established at the time of the
installation.
Proper gas pressure provides a consistent flow of
gas to the appliance and is instrumental in checking for
gas leaks.The gas control valve on the insert is equipped
with pressure test points for gauge connections. The
gauge connections are located on the front of the valve
under the On/Off/Pilot knob. See fig. 13.
IIIIIN / E
N / E
N / E
N / E
N / E for inlet
inlet
inlet
inlet
inlet or supply pressure (the amount of gas
coming to the valve.)
OU
OU
OU
OU
OUT / A
T / A
T / A
T / A
T / A for manif
manif
manif
manif
manifold
old
old
old
old pressure (the amount of gas that
is coming out of the valve to the burner.)
The appliance must be isolated from the gas supply
line by closing its individual manual gas shut-off valve
(gas cock) during any pressure testing of the gas supply
piping system that is equal to or exceeds pressures
of 1/2 psig (3.5kPa).
NECESSARY INLET GAS PRESSURES (inches
water column)
MIN
MAX
NATURAL GAS
5.0 WC
13.5 WC
PROPANE
11.0 WC
13.5 WC
NECESSARY MANIFOLD PRESSURES
(inches water column)
MIN MAX
NATURAL GAS
2.2 WC
3.5 WC
PROPANE
6.5 WC
10.0 WC
ALWAYS TEST PRESSURE WITH VALVE CONTROL
KNOB SET ON HIGH.
Figure 12. Gas connection components.
GAS
LINE
CONNECTION
Figure 11. Valve inlet centerline.
1 1/4”
7 3/16”
E
A
Figure 13. Pressure test points.
Содержание GI 450 DV Katahdin
Страница 2: ...2...