background image

Users, 

Installation & Servicing

 

Instructions 

 

MUST BE LEFT WITH THE USER 

 

ACCOLADE

 

 

Fuel Effect Options: 

Coal Effect – NG and LPG 

Pebble Effect – NG and LPG 

 

Control Options: 

Manual BM Control 

Upgradeable Manual Control 

Remote Control 

Optimum Control 

 
 

 

For use on Natural Gas (G20) at a supply pressure of 20mbar  

or Propane (G31) at a supply pressure of 37mbar in GB and IE 

(Dependent upon model)

 

Summary of Contents for ACCOLADE

Page 1: ...t Options Coal Effect NG and LPG Pebble Effect NG and LPG Control Options Manual BM Control Upgradeable Manual Control Remote Control Optimum Control For use on Natural Gas G20 at a supply pressure of...

Page 2: ...ng within one year of purchase Burley Magiglo will arrange to repair or replace the item free of charge Any claims under this warranty must be made through the retailer from whom the product was purch...

Page 3: ...es 19 2 8 2 Cleaning the Pilot 20 2 8 3 Cleaning the Fire Back 20 2 8 4 Black Painted Metal Surfaces 20 2 8 5 Brass or Polished Surfaces 22 2 8 6 Stainless Steel 22 2 8 7 Care of Ceramic Backs 22 3 In...

Page 4: ...tructions 40 4 3 Replacing Parts 41 4 3 1 Pilot Assembly Replacement 41 4 3 2 Injector Replacement 41 4 3 3 Control Valve Replacement 42 4 3 4 Motor Replacement Remote Control Optimum Control Models 4...

Page 5: ...andards BS 5871 Pt 2 Installation of Inset Live Fuel Effect Gas Fires BS 6891 Pipe work Installation BS 5440 Pts 1 2 Flues and Ventilation BS EN 1856 Chimneys Requirements for metal chimneys System ch...

Page 6: ...858 or BS 1289 Pt 1 and having a minimum cross sectional area of 12 272mm2 with the smallest dimension being no less than 63mm Please refer to the full Flue and Chimney Requirements within the Install...

Page 7: ...inimum of 5 square inches of free air space below the base of the fire Minimum opening free air in fire fret Minimum opening free air in ash pan cover Figure 1 Fire Front Specification Height to Centr...

Page 8: ...Page 4 This page is left intentionally blank...

Page 9: ...m on your fire as shown and follow the appropriate operating instructions in the appropriate section Control Valve Operation Control Type Manual Manual BM Control See Section X2 1 1X on Page X6X Manua...

Page 10: ...lighted match or taper to the pilot jet and following the above procedure NOTE No attempt should be made to relight the fire for at least 3 minutes after the pilot flame has been extinguished either...

Page 11: ...X 4 Turn the GAS RATE ADJUSTING KNOB fully anticlockwise until you reach the stop position i e the maximum gas rate See XFigure 10X 5 The main burner will have cross lit from the pilot 6 Now the gas r...

Page 12: ...heard from the valve During this process the main burner will ignite from the pilot 8 By pressing the two buttons together to increase the gas rate and the lower button only to decrease the gas rate...

Page 13: ...lame position 7 Press and hold the large flame button in XFigure 13X until clicking is heard fully open 8 The main burner will have cross lit from the pilot 9 Now the gas rate can be adjusted to the d...

Page 14: ...Receiver Unit 1 Remove the receiver unit from under the fire burner or from wherever positioned if mounted remotely and remove the battery compartment cover see diagram 2 Replace the old batteries wit...

Page 15: ...wdriver 3 Remove the battery pack from the wall box and replace the spent batteries with new ones 4 off 1 5V AA batteries ensuring correct polarity 4 Insert the battery pack back into the wall box and...

Page 16: ...ervicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire to ensure that the release of fibres from...

Page 17: ...bridging between the front matrix and the rear matrix see XFigure 23X XFigure 24X shows how not to lay the rounded coals 5 Bridge the three Large Triangular coals between the rear matrix and the roun...

Page 18: ...Page 14 Figure 25 Figure 26 Gap Tip Forward Figure 27 WARNING Do not touch the fire when it is alight The fire will remain very hot for a while after extinguishing...

Page 19: ...30X such that they are bridging between the front and rear matrix 4 Place pebbles A B on the rear matrix as shown in Figure 8 such that they are supported in front by the pebbles laid in step 3 5 Plac...

Page 20: ...se the trim as necessary Magnets Figure 32 2 6 Fitting an ioss Firebox Fascia if supplied 1 The Fascia is coated with a protective film This must be removed by peeling off before fitting the fascia 2...

Page 21: ...erally heating appliances will create warm air convection currents that will transfer heat to any wall surface against which they are located Some soft furnishings including blown vinyl wallpapers may...

Page 22: ...broken up but are sealed within heavy duty polythene bags and clearly labelled as RCF waste RCF waste may be disposed of in suitably licensed landfill sites 2 8 1 Cleaning the Fire Bed and the Imitat...

Page 23: ...e offending blockage 1 Using a pair of tweezers if available or a piece of fine soft wire pick out the lint from the lint guard 2 With the aid of a small nozzle attachment on your vacuum cleaner apply...

Page 24: ...moved the surface can then be re polished using 3M Scotchbrite pads Fine Grade Periodically it may be necessary to coat the entire surface in order to achieve a uniform finish This can be achieved by...

Page 25: ...flue or chimney may result in smoke and fumes entering the room 3 The flue should be sound free from obstructions and if it has previously been used with a solid fuel or oil fired appliance it should...

Page 26: ...e Milner back Figure 35 Masonry Flue 10mm min Figure 36 Pre Cast Flue to BS EN 1858 or BS 1289 125 mm Figure 37 BS 715 Flue Box Fireplace Opening Size mm Applies to all cases Min Max 54BHeight 540 575...

Page 27: ...irable not to include a hearth with the appliance installation Building Regulation Approved Document J paragraph 3 40 currently states Appliance should be placed on hearths unless a they are installed...

Page 28: ...andescent material HD Must project a minimum of 300mm in front of any naked flame or incandescent material Table 3 Other dimensions are dependent on flue construction and fireplace design therefore pl...

Page 29: ...mounted decorative bar etc W Must project a minimum of 150mm either side of any naked flame or incandescent material D Must project a minimum of 300mm in front of any naked flame or incandescent mater...

Page 30: ...le of physical barrier dimensions as stated in XTable 4 Protected AreaX D W Figure 47 Example of physical barrier dimensions as stated in XTable 4 Protected AreaX D W 50mm Min Figure 48 Example of phy...

Page 31: ...ting the fire in Northern Ireland NI purpose provided ventilation must be provided in accordance with the rules in force In other EC countries equivalent rules in force must be used 3 6 Technical Data...

Page 32: ...G LPG 1 Trim Optional 1 Fire Front 1 pack Cable Fixing Kit Length of Sealing Strip Instruction booklet Isolating valve Flue Restrictor Plate 3 fixing screws Additional Items for Remote Control Models...

Page 33: ...move the front plate by removing the two fixing screws see XFigure 51X 2 Remove the three tray fixing screws located under the front corners of the tray see XFigure 52X 3 Withdraw the burner from the...

Page 34: ...fireplace opening in accordance with section X3 2X X3 3X and X3 4X 2 Mark out drill plug and fit the four cable guide brackets onto the rear wall of the fireplace opening as shown in XFigure 55X Use 4...

Page 35: ...each bare cable end into the hole at the threaded end of the cable tensioning screw see XFigure 57X 5 Slide it all the way onto the cable and through the 8mm diameter hole in the firebox If required t...

Page 36: ...the inlet tubing on the control valve This is used for marking purposes 3 Re place the burner into the firebox and mark the desired position of the gas inlet pipe 4 Remove the burner cut the gas inle...

Page 37: ...hield to the spade terminals on the control valve keeping the cable clear of the underside of the burner The cable connectors must be matched to the appropriately sized spade connector 4 Position the...

Page 38: ...motor on the valve ensuring correct polarity The cable connectors must be matched to the appropriately sized spade connector Also ensure that the cable is neatly tucked away and not touching the under...

Page 39: ...point is 20 1 0mbar for Natural Gas or 37 1 0mbar for Propane working pressure 6 If the correct pressure cannot be achieved then some potential causes of low pressure are a Supply pipes are not of la...

Page 40: ...oors open between the fans and the fire 5 If the fire shows tendency to spill this may indicate either an installation fault or a flue construction fault Disconnect the fire and seek expert advice The...

Page 41: ...the gas and electrical supply where applicable have been isolated After any servicing or replacement of any parts the appliance should be re commissioned 4 2 Servicing Instructions As part of the appl...

Page 42: ...NOTE If any part of the pilot assembly becomes faulty then the whole pilot assembly will need changing 1 Remove the HT lead from the end of the electrode 2 Cut the cable tie wrap 3 Using M9 spanner un...

Page 43: ...circuit 2 Remove the two motor connection tags from the valve 3 Remove the valve cover securing screw 4 Unclip the valve cover from the valve on the left hand side by inserting a very small screwdriv...

Page 44: ...eased a Loose thermocouple connection at control valve end Remake thermocouple ensuring the connection is firm b Faulty Thermocouple Replace complete pilot assembly Pilot and main burner go out when c...

Page 45: ...lace all 4 AA batteries c Flat batteries in battery holder Optimum Control Replace all 4 AA batteries Remote Control will turn fire off but will not turn on Incorrect hand set operation Ensure two but...

Page 46: ...Page 42 This page is left intentionally blank...

Page 47: ...Page 43 This page is left intentionally blank...

Page 48: ...patents 2193802 2240620 and 2256920 Other Patents Pending Magiglo is a registered trademark of Burley Appliances Ltd Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01...