background image

15

Flame Adjustment / Air Shutter

THE KATAHDIN GAS INSERT IS SHIPPED FROM THE
FACTORY EQUIPPED FOR USE WITH NATURAL GAS.
WHEN USING PROPANE, IT WILL BE NECESSARY TO
ADJUST THE AIR SHUTTER ON THE BURNER TUBE TO
ACHIEVE THE PROPER GAS TO AIR MIX.  See fig. 15.

WARNING:

AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE

PERFORMED BY A QUALIFIED PROFESSIONAL

SERVICE TECHNICIAN.

The air shutter adjustment can also help achieve

the desired flame appearance.  Generally, flame appear-
ance is a matter of preference, however most consum-
ers enjoy the warm, yellowish flame.

Closing 

Closing 

Closing 

Closing 

Closing the Air Shutter

the Air Shutter

the Air Shutter

the Air Shutter

the Air Shutter -  Insufficient combustion

air will result in very long yellow flames that can
promote soot.  Sooting produces black deposits on the
logs, on the inside walls of the appliance, and poten-
tially on the exterior termination cap.

Sooting is caused by incomplete combustion in the

flames and lack of combustion air entering the air
shutter opening.

Opening 

Opening 

Opening 

Opening 

Opening the air shutter

the air shutter

the air shutter

the air shutter

the air shutter - will generate a flame

that is blue and transparent, or an “anemic” flame.  This
flame is generally more efficient, but not very attrac-
tive.

Jøtul recommends the following settings for the

Katahdin gas insert:

Pr

Pr

Pr

Pr

Propane:

opane:

opane:

opane:

opane:  1

  1

  1

  1

  1/////4”

4”

4”

4”

4” open

 open

 open

 open

 open

Na

Na

Na

Na

Natur

tur

tur

tur

tural Gas:

al Gas:

al Gas:

al Gas:

al Gas:  1

  1

  1

  1

  1/////4”

4”

4”

4”

4” open

 open

 open

 open

 open

REMEMBER:  Run the insert for a minimum of 15 to

20 minutes for an accurate representation of the flame
appearance. This should be done before and between
any air shutter adjustments.

T

TT

T

To adjust

o adjust

o adjust

o adjust

o adjust     the air shutter

the air shutter

the air shutter

the air shutter

the air shutter

1. Remove the burner tube and using a phillips head

screwdriver loosen the screw at the air shutter and
adjust accordingly.

2. Be sure to retighten the screw that holds the air

shutter setting.

3. Reassemble the insert including glass assembly.

Allow insert to burn 30 minutes on the HIGH setting,
observing the flame continuously.

4. If the flame appears weak, slow, or sooty, repeat the

process described above until the flame is as desired.

Installing the Log Set

NO

NO

NO

NO

NOT

TT

T

TE:

E:

E:

E:

E: Install 

 Install 

 Install 

 Install 

 Install the optional An

the optional An

the optional An

the optional An

the optional Antique Brick P

tique Brick P

tique Brick P

tique Brick P

tique Brick Panels

anels

anels

anels

anels

bef

bef

bef

bef

befor

or

or

or

ore installing 

e installing 

e installing 

e installing 

e installing the L

the L

the L

the L

the Log Set

og Set

og Set

og Set

og Set.....

The Katahdin is equipped with a three piece log set
packaged in bubble wrap inside the firebox. The log set
must be removed from the packaging and arranged in
the unit prior to start up of the gas insert. Protect your
hands by wearing gloves to prevent skin irritation from
the ceramic fibers.

1.  Unwrap each log and set on floor near unit.

2.  Lift out andiron.

3.  Place rear log over the  rear log pins in the rear of the

firebox. The rear log should be installed with the
tapered end of the log on the right.

Figure 16.  Log identification.

Burner Tube

Air Shutter

NOTE:  A

IR

 

SHUTTER

 

SHOULD

 

NEVER

 

BE

            LESS 

THAN

 1/8” 

OPEN

.

Figure 15.

Cross-over Log

Pin

Rear Log

Pin

Front Log

Содержание GI 450 DV Katahdin

Страница 1: ...or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call you gas supplier from a n...

Страница 2: ...2...

Страница 3: ...eration 20 Maintenance 20 Service Log 21 Illustrated Parts Diagram 22 Replacement Parts 23 Antique Brick Panel Kit 24 Appendix Leg Levelers 26 Lighting Instructions BACK COVER J tul GI DV Katahdin Dir...

Страница 4: ...ch Pipe sealant 10mm open end wrench 1 2 7 16 open end wrench Phillips head screwdriver Flat head screwdriver 1 4 nut driver Gloves Safety glasses Torx T20 screwdriver Leak test solution 15 3 8 Input...

Страница 5: ...tels reglements selon les Codes d installation CAN CGA B149 DO NOT OPERATE THIS INSERT IF ANY PART HAS BEEN UNDER WATER Immediately call a qualified service technician to inspect the heater and to re...

Страница 6: ...f ound f ound f ound for installa or installa or installa or installa or installations tions tions tions tions tha tha tha tha that t t t t include include include include include the 2 the 2 the 2 th...

Страница 7: ...uct THE GAS APPLIANCE AND VENT SYSTEM MUST BE VENTED DIRECTLY TO THE OUTSIDE OF THE BUILD ING AND NEVER ATTACHED TO A CHIMNEY SERVING A SOLID FUEL OR GAS BURNING APPLIANCE The minimum vent height abov...

Страница 8: ...cap is required to allow fresh air into the chimney flue and ultimately into the intake duct to the insert 9 9 9 9 9 Compress the ducts so that they are hanging above the height of the fireplace openi...

Страница 9: ...12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 1...

Страница 10: ...the fireplace face D 38 D 38 D 38 D 38 D 38 915mm 915mm 915mm 915mm 915mm t t t t to a Man o a Man o a Man o a Man o a Mantel tel tel tel tel that extends no more than 14 1 2 from the fireplace face N...

Страница 11: ...en tents ts ts ts ts 1 regulator tower labeled for propane 3 regulator tower screws 1 burner orifice 31 NG 51 LPG 1 pilot orifice 30 for LPG 51 for NG Label A applied to the base of the insert Label B...

Страница 12: ...N AN AN ANT T T T T Correct gas pressure is essential for efficient and safe operation of the Katahdin gas insert It is important that the correct gas pressure be established at the time of the instal...

Страница 13: ...appliance and is instrumental in checking for gas leaks The gas control valve on the insert is equipped with pressure test points for gauge connections The gauge connections are located on the front o...

Страница 14: ...WORK ASSUMES RESPONSI BILITY FOR THIS DERATING In C In C In C In C In Canada anada anada anada anada This unit has been tested for installation at high alti tudes in accordance with Canadian test stan...

Страница 15: ...for an accurate representation of the flame appearance This should be done before and between any air shutter adjustments T T T T To adjust o adjust o adjust o adjust o adjust the air shutter the air...

Страница 16: ...TH H H H HE PL E PL E PL E PL E PLUG UG UG UG UG The blower must be electrically grounded in accor dance with local codes or in the absence of local codes with the current NFPA 70 National Electrical...

Страница 17: ...TION AFTER SERVICING THE APPLIANCE ATTENTION AU MOMENT DE L ENTRETIENDES COMMANDES ETIQUETEZTOUS LES FILS AVANT LE DEBRANCHEMENT DES ERREURS DE CABLAGE PEUVENT ENTRAIUN FONC TIONNEMENT INADEQUAT ET DA...

Страница 18: ...T TAB AB AB AB ABI I I I ILIZER B LIZER B LIZER B LIZER B LIZER BAR AR AR AR AR THAT IS SHIPPED WITH THE UNIT THIS STABILIZER ATTACHES TO THE OUTSIDE OF THE FIREBOX AND WILL BRACE THE UNIT AGAINST THE...

Страница 19: ...ra tor and the top 1 8 of the quick drop out thermo couple The pilot flame should project out of the pilot hood 1 at all three ports See Figure 28 8 Slide the surround down into the mounting holes Be...

Страница 20: ...dampened soft cloth Follow with a dry soft towel as desired Take care not to scratch the glass surface WARNING DO NOT USE ABRASIVE CLEANERS ON THE GLASS NEVER CLEAN THE GLASS WHEN IT IS HOT Maintenan...

Страница 21: ..._____ TYPE OF FUEL ___________________________________ FUEL CONVERSION NO _______ YES______ NOTES _________________________________________ _______________________________________________ ____________...

Страница 22: ...10 12 7 14 34 16 18 26 25 22 24 21 20 19 16 15 27 14 28 29 8 13 10 11 4 3 30 9 32 17 23 33 J tul GI J tul GI J tul GI J tul GI J tul GI 450 D D D D DV K V K V K V K V Ka a a a a tahdin tahdin tahdin...

Страница 23: ...tch 220703 33 Exhaust Baffle 220712 GI 450 DV Katahdin Parts List SURROUND PARTS Matte Black Blue Black J tul Iron 1 Breast Plate Left 10394092 10394027 10394085 2 BreastPlate Right 10394192 10394127...

Страница 24: ...e with the cutout in the side panel 6 Install the Left Side Panel Lift the lower panel up enough to allow the side panel to clear it Be sure to push the side forward up against the firebox front 7 Ins...

Страница 25: ...25 Figure 35 Install Left Side Panel Figure 36 Install Upper Rear Panel...

Страница 26: ...clearance remain unchanged from those specified in the Operation Manual Raising the firebox higher than 2 will require that the clearance to mantel and trim be increased by 1 Hearth to Upper Trim 37 H...

Страница 27: ...as is heavier than air and will settle to the floor W W W W WHA HA HA HA HAT T T T T T T T T TO DO I O DO I O DO I O DO I O DO IF F F F F Y Y Y Y YOU S OU S OU S OU S OU SMELL G MELL G MELL G MELL G M...

Страница 28: ...the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specificati...

Отзывы: