![Johnson Controls York AYK550 Скачать руководство пользователя страница 258](http://html1.mh-extra.com/html/johnson-controls/york-ayk550/york-ayk550_user-manual_2023914258.webp)
%
$$&G %
YORK, A Johnson Controls Company
IGBT Test Method
The following procedure will check the inverter transis-
tors (IGBTs) and diodes:
1. Disconnect input power to terminals (U
1
, V
1
, and
W
1
) and motor terminals (U
2,
V
2,
, and W
2
).
2. Disconnect any wires from terminals (UC+) and
(UC-) for regenerative braking.
3. Use a Digital Volt Meter (DVM) and set it for 1 ohm
resistance range. You can check the status of the
charging state of terminals (U
1
, V
1
, W
1
, U
2
, V
2
, W
2
,
UC+, and UC-) of the inverter and the probe of the
DVM by measuring the charging state.
Almost infinite ohms = “nonconducting,” and 0 to 10
ohms = “conducting.”
NOTE:
The resistance values for the diodes or the
transistors will not be exactly the same, but
they will be close. If you find a significance
difference, a problem may exist.
CIRCUIT TYPE
+ -
MEASURED VALUE
DVM
PROBE
Inverter Component Values
OUTPUT
CONVERTER
SECTION
INPUT
CONVERTER
SECTION
D3
U
1
UC+
Conducting
UC+
U
1
Nonconducting
D2
V
1
UC+
Conducting
UC+
V
1
Nonconducting
D1
W
1
UC+
Conducting
UC+
W
1
Nonconducting
D6
U
1
UC-
Nonconducting
UC-
U
1
Conducting
D5
V
1
UC-
Nonconducting
UC-
V
1
Conducting
D4
W
1
UC-
Nonconducting
UC-
W
1
Conducting
TR3
U
2
UC+
Conducting
UC+
U
2
Nonconducting
TR2
V
2
UC+
Conducting
UC+
V
2
Nonconducting
TR1
W
2
UC+
Conducting
UC+
W
2
Nonconducting
TR6
U
2
UC-
Nonconducting
UC-
U
2
Conducting
TR5
V
2
UC-
Nonconducting
UC-
V
2
Conducting
TR4
W
2
UC-
Nonconducting
UC-
W
2
Conducting
1
2
%
2
3
2
1
4
%
4
3
4
1$5
1$6
7$ "
Содержание York AYK550
Страница 254: ...G YORK A Johnson Controls Company Bypass Package Components Note Solution AHU Does Not have VFD Input Service Switch...
Страница 259: ...YORK A Johnson Controls Company G 8 Fig 1 7 8 94 4 7...
Страница 260: ...G YORK A Johnson Controls Company Fig 2 7 8 8 94 7...
Страница 261: ...YORK A Johnson Controls Company G 7 8 6 8 94 7 Fig 3...
Страница 262: ...G YORK A Johnson Controls Company Fig 4 7 8 8 94 2 7...
Страница 263: ...YORK A Johnson Controls Company G Fig 5 7 8 6 8 94 7...
Страница 264: ...G YORK A Johnson Controls Company Fig 6 7 8 8 8 94 7...
Страница 265: ...YORK A Johnson Controls Company G Fig 7 7 8 8 94 7...
Страница 266: ...2 G YORK A Johnson Controls Company Fig 8 7 8 H 8 94 4 7...
Страница 267: ...3 YORK A Johnson Controls Company G Fig 9 7 8 6 H 8 94 7...
Страница 268: ...G YORK A Johnson Controls Company 7 8 8 8 94 7 Fig 10...
Страница 269: ...YORK A Johnson Controls Company G Fig 11 J 8 8 94 7...