TEC2104-3 N2 Networked Multi-Stage Economizer Thermostat Installation Instructions

16

Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.

All other marks herein are the marks of their respective owners. © 2009 Johnson Controls, Inc.

Building Efficiency

507 E. Michigan Street, Milwaukee, WI  53202

Technical Specifications      

TEC2104-3 N2 Networked Multi-Stage Economizer Thermostat

Power Requirements

19 to 30 VAC, 50/60 Hz, 2 VA (Terminals RC and C) at 24 VAC Nominal, Class 2 or 
Safety Extra-Low Voltage (SELV)

Relay Contact Rating

30 VAC, 1.0 A Maximum, 3.0 A In-Rush, Class 2 or SELV

Digital Inputs

Voltage-Free Contacts across Terminal C to Terminals DI1 and DI2

Economizer Output

0 to 10 VDC into 2k ohm resistance minimum

Wire Size

18 AWG (1.0 mm Diameter) Maximum, 22 AWG (0.6 mm Diameter) Recommended

Temperature Sensor Type

Local 10k ohm Type II Negative Temperature Coefficient (NTC) Thermistor

Temperature 
Range

Backlit 
Display

-40.0°F/-40.0°C to 122.0°F/50.0°C in 0.5° Increments

Heating 
Control

40.0°F/4.5°C to 90.0°F/32.0°C

Cooling 
Control

54.0°F/12.0°C to 100.0°F/38.0°C

Accuracy

Temperature

±0.9F°/±0.5C° at 70.0°F/21.0°C Typical Calibrated

Default Minimum Deadband

2F°/1C° between Heating and Cooling

Ambient 
Conditions

Operating

32 to 122°F (0 to 50°C); 95% RH Maximum, Noncondensing

Storage

-22 to 122°F (-30 to 50°C); 95% RH Maximum, Noncondensing

Compliance

United States

UL Listed, File E27734, CCN XAPX, 
Under UL 873, Temperature Indicating and Regulating Equipment

FCC Compliant to CFR 47, Part 15, Subpart B, Class A

Canada

UL Listed, File E27734, CCN XAPX7, 
Under CAN/CSA C22.2 No. 24, Temperature Indicating and Regulating Equipment

Industry Canada, ICES-003

Europe

CE Mark, EMC Directive 89/336/EEC

Australia and 
New Zealand

C-Tick Mark, Australia/NZ Emissions Compliant

Shipping Weight

0.75 lb (0.34 kg)

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these 
specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or 
misuse of its products.

Содержание TEC2104-3

Страница 1: ...injury or property damage to the controlled equipment or other property additional precautions must be designed into the control system Incorporate and maintain other devices such as supervisory or a...

Страница 2: ...he thermostat mounting base so that the arrow on the base points upward to indicate the top of the thermostat 6 Drill a 3 16 in 5 mm hole at each of the two marked locations and tap nylon anchors incl...

Страница 3: ...ANT Make all wiring connections in accordance with local national and regional regulations Do not exceed the electrical ratings of the TEC2104 3 Thermostat Figure 5 Wiring the TEC2104 3 Thermostat 24...

Страница 4: ...etpoint if necessary to maintain the minimum deadband between the two setpoints The setpoints can be spread farther apart but can never be adjusted closer than 2F 1C apart If a supervisory controller...

Страница 5: ...m Heat SP ADI 7 N2 AI CSAD 40 F 4 5 C Maximum Heat SP1 ADI 8 N2 AO CSAD 40 to 90 F 4 5 to 32 C Minimum Cool SP1 ADI 9 N2 AO CSAD 54 to 100 F 12 to 37 5 C Maximum Cool SP ADI 10 N2 AI CSAD 100 F 37 5 C...

Страница 6: ...ithin the limits for a command results in an N2 Negative Acknowledge NAK error from the TEC2104 3 thermostat Overrides take precedence over any local adjustment or command in the TEC2104 3 thermostat...

Страница 7: ...o activate a setpoint adjustment Backlit Liquid Crystal Display LCD The TEC2104 3 Thermostat includes a 2 line 8 character backlit display Low level backlighting is present during normal operation and...

Страница 8: ...the YES key at the exit prompt To pass over a parameter without changing it press the NO key When the thermostat is in the Installer Configuration Menu and left unattended for approximately 8 seconds...

Страница 9: ...cess No Access No Access Temporary Temperature Setpoints Access Access No Access System Mode Setting Access No Access No Access Fan Mode Setting Access No Access No Access Pwr del1 Sets the delay time...

Страница 10: ...er a heating or cooling cycle has ended The fan delay is only active when the fan is in the Auto mode Com addr N2 network address at the thermostat coincides with the address assigned at the superviso...

Страница 11: ...n o n c Contact open Occupied contact closed Unoccupied n o Contact closed Occupied contact open Unoccupied The contact toggles with the internal Occupied Unoccupied schedule or the NSB contact on on...

Страница 12: ...er Resuming the Programmed Schedule This menu only appears when the thermostat is in the unoccupied override mode To resume the schedule while in the Main User Menu 1 Press the NO key to all prompts u...

Страница 13: ...Thermostat Display Description Press the MENU key while in the Status Display Menu to enter the Main User Menu Press the NO key to all prompts until the temperature setpoint prompt appears on the disp...

Страница 14: ...ccupied and unoccupied states Smart Fan Mode smart Energizes the fan all the time for occupied states and only on a call for heating or cooling in unoccupied states This is the default setting To sele...

Страница 15: ...more controllers have the same address Change each duplicate address to a unique number The N2 Bus contains too many devices Do not exceed the maximum number of devices allowed on the N2 Bus per super...

Страница 16: ...acklit Display 40 0 F 40 0 C to 122 0 F 50 0 C in 0 5 Increments Heating Control 40 0 F 4 5 C to 90 0 F 32 0 C Cooling Control 54 0 F 12 0 C to 100 0 F 38 0 C Accuracy Temperature 0 9F 0 5C at 70 0 F...

Отзывы: