background image

NORMAL OPERATION

By pressing the 

ON/OFF (1)

 button, the devices 

enters normal operation mode. The display 
shows the current temperature of the hot air and 
the indicators show the operation mode of the 
blower.

OPERATION MODE SELECTION

By pressing the 

MENU (2) 

button we can select 

the operation mode between MANUAL, 
SEMIAUTOMATIC and AUTOMATIC. The 
operation mode is shown from the respective 
indicators 

(6), (7), (8)

.

MANUAL OPERATION

 

(ΜΑΝ)

In this mode of operation the only setting that can 
be adjusted is the blower speed. 

With the keys 

``

+

`` 

(4)

 and ``

-

`` 

(3)

 we can select the desired 

speed which is steady and independent of the 
temperature.

SEMIAUTOMATIC OPERATION (SEMI)

It is basically the same operation as the manual 
operation mode with the only difference that the 
blower operates only when the temperature of 
the hot air is higher that the activation 
temperature        

AUTOMATIC OPERATION

 

(AUTO)

In this mode of operation, the speed of the blower 
is automatically adjust depending on the 
temperature of the hot air. 

The speed is minimum 

when the hot air temperature exceeds the 

940841000_09_007

Page 1 from

 

5

PROGRAMMABLE THERMOSTAT FOR FIREPLACES

 BS-841

DESCRIPTIONS

 

OF CONTROL BUTTONS

-

INDICATORS

(1)

. ON-OFF button

(2)

Settings selection button

(3)

Decrease button

(4)

Increase button

(5)

LED screen

(6)

. Manual operation indicator

(7)

Semiautomatic operation indicator

(8)

Automatic operation indicator

(9)

Blower operation indicator

  

OPERATION

STANDBY MODE

When the product is connected for the first time to 
the mains power supply it goes into standby mode. 

In 

the opposite condition press the 

ON/OFF

 button. 

The 

display shows 3 dashes and all the indicators are 
OFF. In this mode, the device is practicaly not 
operational.

(6)

(8)

(7)

(9)

(1)

(3)

(2)

(4)

(5)

TECHNICAL CHARACTERISTICS

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

SENSOR CONSTRUCTION MATERIAL

EXTERNAL DIMENSIONS
TYPICAL WEIGHT

 (

Main unit

 / + 

sensor

)

GUARANTEE

OPERATION VOLTAGE

CONSUMPTION

(

without the blower

)

BLOWER OUTPUT RATING

SENSOR MEASUREMENT RANGE

SENSOR RATING

BLOWER OUTPUT PROTECTION

BLOWER POWER ADJUSTMENT

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

INDICATORS
SETTING TYPES
SENSOR LENGTH

CONTROL BUTTONS

220-240V AC/45-55Hz

20% - 90%

o

o

-40 C to 250  C

Internal replaceable fuse

o

o

Up to 

250

C for the sensor head

up to

 200

C

 

for the cable

Types

User and Installer

2

50 cm

Stainless steel head

silicon cable

200W max

,85A

 

(

0

)

  MANUAL

SEMIAUTOMATIC

AUTOMATIC

BLOWER

  MENU, +, -, ON/OFF

3VA / 2,5W max.

EN 61000-6-1, EN 61000-6-3, EN 60730-1, EN 60730-2-9

IP 20

-10 to 60  C

o

0 -

 90% RH 

2 years

2

4

0gr / 3

1

0gr

137 

9

5 x 

40

 mm 

High Quality European based Manufacturers

Содержание BS-841

Страница 1: ...on 2 Settings selection button 3 Decrease button 4 Increase button 5 LED screen 6 Manual operation indicator 7 Semiautomatic operation indicator 8 Automatic operation indicator 9 Blower operation indicator OPERATION STANDBY MODE When the product is connected for the first time to the mains power supply it goes into standby mode In the opposite condition press the ON OFF button The display shows 3 ...

Страница 2: ...er that the blinking current value The value refers to the overheating level of the fireplace and can be adjusted between 100 C and 200 C using the buttons and When the temperature of the hot air exceeds this limit the buzzer sounds and the blower is activated with a maximum o o o o o o o o o o Page 2 from 5 activation temperature and gradually increase until is reaches it s maximum value The butt...

Страница 3: ...and 30 C by using the buttons και 8 RESETTING TO FACTORY DEFAULT SETTINGS in programing mode With a ninth press of the MENU button the display shows the message Factory If one of the buttons or is pressed then all the settings are restored to factory defaults Every new press of the MENU button from this point on repeates the setting cycle In order to complete and store the settings press the ON OF...

Страница 4: ...terminal The SENSOR is connected to the S1 S2 terminals and it is installed in the measuring point with the included screw The BLOWER cables are connected to the M1 M2 terminals 4 After all the connections are finished replace the front plastic cover and install the fastening screws Place the included cups and the device is now ready to be activated 3 Installation instructions REPLACING THE FUSE 1...

Страница 5: ...ng done by a third party unless Olympia Electronics has fully agreed to them in writing Olympia Electronics reserves the right to repair or to replace the returned goods and to the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost Products that have been damaged can be returned to the premises of our company for rep...

Отзывы: