940841000_09_007
Page 4 from
5
SENSOR
Dimensions in mm
1 To install the device, remove the front plastic cover by
unfastening the retaining screws.
2
Produce the required opening to install the plastic base, after
opening the pre etched cable entries.
ATTENTION!!! Make sure that the operation temperature of the
device in the installation area, must not exceed the operation
limits.
3
Make the electrical connections as shown in the diagram
.
Connect the neutral cable to the
N
terminal, connect the phase
terminal to the
L
terminal and connect the ground cable to the
POWER EARTH terminal.
WARNING
!!!
Every metallic part of the fireplace should
be connected to the ground terminal.
The SENSOR is connected to the S1, S2 terminals and it is
installed in the measuring point with the included screw. The
BLOWER cables are connected to the M1, M2 terminals.
4
After all the connections are finished, replace the front plastic
cover and install the fastening screws. Place the included cups
and the device is now ready to be activated.
3
Installation instructions
REPLACING THE FUSE
137
95
40
If the blower is not operating then the most usual cause is a
faulty fuse. To replace the fuse, the top cover must be
removed according to step 1 of the installation instructions.
Use a needle nose plier to remove the faulty fuse (as show in
the photo) and replace it with a new fuse of the same type
and rating. Refit the top cover according to step 4
of the
installation instructions.
1
3
2
1
15
The required opening to install
the plastic base in mm.
73
N
L