HUMLOG 10 

Manual

 

 

 

 

 

 

 

 

 

 

Содержание HUMLOG 10

Страница 1: ...Status V2 12 2003 HUMLOG 10 Manual ...

Страница 2: ... 3 HUMLOG 10 WITH INTERNAL SENSORS 6 4 HUMLOG 10 TSE FOR EXTERNAL SENSORS 7 5 HUMLOG 10 THC WITH INTERNAL SENSORS WITHOUT DISPLAY 9 6 CHANGING THE SENSOR MODULE 13 7 CHANGING THE BATTERY 14 8 MOUNTING THE HUMLOG 10 15 9 SWITCHING ON THE HUMLOG 10 16 10 TIPS AND TRICKS 17 ...

Страница 3: ...ither 2 temp probes or 1 2 combined humidity temp probe can be connected HUMLOG 10 THC humidity temperature internal without display Due to its extremely low energy consumption and large memory the product is excellently suited to long term measurement in both mobile and stationery applications The SmartGraph 2 software which is included with the product offers the user an overview presentation an...

Страница 4: ...roprocessor controller are located on the Display Module Illustration HUMLOG 10 Display Elements Alarm Channel 1 Alarm Channel 2 Special Functions Channel 1 Unit Channel 2 Unit REC Recording On STOP Recording Off Display Preselection Mode Active Display Real Time Clock Alternative Display of date time for the preselection or real time Format Date 12 10 Format Time 12 10 ...

Страница 5: ...exceeded The alarm message can only be eliminated by selecting Memory Readout on the PC If the Pre Selection mode start flag was selected the start date and start time for data recording are shown on the Date Time display Once the pre set date time has been reached the start flag is eliminated the real time clock display becomes active and data recording begins The units m s Channel 1 and ppm hPa ...

Страница 6: ...ors Necessary calibration intervals are dependent on the environm ental conditions and the requirements of the permissible tolerance deviations A single point calibration of the internal sensors can be carried out using a comparison standard The captured offset values can be entered in the SmartGraph software under Measuring Instrument Manage Measuring Instrument Sensor Electronics Two point calib...

Страница 7: ...y sensors can be connected here Two sensors are only available in connection with the Professional version of SmartGraph 2 If only one external sensor is used this is connected to the left hand sensor socket In order that the instrument may correctly recognise the association of the sensors to the channels both sensor socket positions must first be unoccupied If a sensor is connected to one of the...

Страница 8: ...ge Measuring Instrument Sensor Electronics Two point calibrations can only be carried out in the factory Instructions for using additional extensions for the probes The probes are adjusted for the standard cable with a length of 2m By using extension cables for the probes the accuracy of the measured relative humidity degrades Using an additional extension cable with a length of 2m or 4m no change...

Страница 9: ...t identical to the hardware of the HUMLOG10 with display Two LEDs a red and a green one are used as a sub stitute for the display to indicate the operation mode and the alarm In addition you will find close to the serial interface a start stop button to switch on off the datalogger Operation mode Alarm Serial interface Start Stop button ...

Страница 10: ...ll start recording by pressing it again the HUMLOG10 will stop etc Important In the start stop mode the HUMLOG10 will start recording from the start date on provided that this date is set in the HUMLOG no matter if the start stop button is being pressed during this time Before the HUMLOG starts recording it can be activated or deactivated too via the on off button s timing diagram Button On Button...

Страница 11: ... to start stop the HUMLOG10 When activating the HUMLOG10 the green LED remains on during 3 sec The red LED remains on during 3 sec when deactivating the HUMLOG10 While recording both LEDs on the HUMLOG10 or just one of them will flash at 10 sec interval This time interval is completely independent of the recording and storage intervals set by the user in the HUMLOG10 Programmed start date ...

Страница 12: ... red LED will flash in case of an alarm If an alarm occurs while the HUMLOG10 is recording the green LED will switch off and the red LED will start flashing As soon as the measured values have become normal again both LEDs will flash to signal that an alarm came up This can be reset by reading out the memory Timing Diagram HUMLOG 10 THC alarms Measuring value Set point LED Green LED Red Readout of...

Страница 13: ...lly remove the HUMLOG 10 back plate with a screwdriver The Sensor Module can now be detached from the display Module Place the new Sensor Module on the display Module guide rail and push the two modules together until they engage Illustration Removing the Back Plate Illustration Assembly of the Modules ...

Страница 14: ...ay facing upwards and carefully remove the upper part of the plastic cover Now remove the old battery and fit the new battery Type LS14500 Saft 3 6V Order No HA 03 01 02 into the holder Important Please observe the correct polarity of the battery and read the safety tips on the battery The BAT indication now disappears and the measurement values are shown again on the display The battery should be...

Страница 15: ...s the HUMLOG 10 may only be mounted on a flat surface In order to do this please first remove the Sensor Module see Changing the Sensor Module Two holes for wall mounting are provided in the guide rail of the Display Module Use these to mount the Display Module Next carefully join the two modules together until they engage Illustration Mounting the HUMLOG 10 ...

Страница 16: ...10 exe Connect the data logger and the serial interface of your PC using the supplied transfer cable Open the menu selection instrument and chose the command read configuration As soon as the first communication has been successfully the measuring values appear on the display and the HUMLOG is ready for operation Remark If difficulties should occur during the communication kindly check your interf...

Страница 17: ...n with the PC reduces battery life Please use only the cable supplied for PC data transfer Please avoid condensation on the sensor electronics and HUMLOG 10 For the entire information and further details regarding handling configuration and evaluation of the data logger kindly have a look at the menu selection help at the enclosed SmartGraph Software ...