PAGE 16 of 89
3
Power button
Activate system power by pressing
(and
releasing)
the silver button.
4
Stop button
The red stop button latches down when
pressed. This stop button shuts down the
system. Twist the stop button clockwise to
return to the released position. This must
be done before power can be activated.
5
SCANLINK
TM
connector
Connection for SCANLINK devices.
6
CTRL socket
Connection for the auxiliary cable.
7
ENC socket
Connection for the encoder cable.
8
Status LCD
Power controller status display.
9
Umbilical connection
Connection for the umbilical.
In the event of a break in the stop circuit
(the stop circuit runs through the power
controller cable, umbilical and the crawler’s emergency stop button)
, the power will
shut off.
NOTE:
Before use, always inspect the power cable and plug for damage. The
power controller should not be used if visible damage is present. The use of
damaged components may be a safety hazard.
4.3.3.1 AC/DC Power Supply
The
1
AC/DC
power supply
(Fig. 26)
is used to connect the power
controller to a suitable 100-240VAC, 50/60Hz grounded power source
capable of supplying a minimum of 5 amps.
The safety of the power controller relies on the provision of a proper
ground connection.
In environments with moisture present, a GFCI
(Ground Fault Circuit
Interrupter)
must be used to ensure operator safety.
NOTE:
Some generators or DC-AC inverters may introduce significant levels
of noise to the system. This may degrade overall system performance
or reduce the system life expectancy. The use of generators or DC-AC
inverters is not recommended and is used at the operator’s risk.