Test Report No.: No.: 17706687 001
Part II of II
Page 33 of 63
EN 61029-1:2009+A11
Clause
Requirement
Test
Result - Remark
Verdict
in the plug or
in a separate control box with one or more
socket outlets in accordance with EN 60309-2
with the earthing contact position 1 h.
PRCDs incorporated in the cord, in the plug or in
a separate control box shall have a degree of
protection against the ingress of water of at least
IPX4.
N/A
21
INTERNAL WIRING
P
21.1
Protection of wiring
P
Reduction of creepage and clearances
P
Damaging of insulation
The wires are so routed that
damage of the insulation is
unlikely.
P
21.2
Protection of internal wiring by enclosure
The basic insulated internal
wires are enclosed by
enclosure.
P
21.3
Wireways
P
Sharp edges, burrs flashes and the like
No Sharp edges, burrs flashes
and the like, which are like to
damage the insulation.
P
Bushings or well-rounded edges for holes in metal
P
Moving parts
There is adequate distance
between internal wire and
moving parts.
P
21.4
Basic insulation of wires and accessible for class II
tools
N/A
21.5
Conductors identified with green/yellow colour
Green/yellow colour only used
by earthing conductor.
P
21.6
Undue stress of wiring between different parts of
the machine
Not applicable
N/A
Protection by flexible metallic tubes
N/A
Protection by open-coil spring
N/A
Flexing of wires
N/A
Flexing test ............................................................... :
N/A
21.7
Distance of 25mm between wires and movable
parts during normal operation
Wiring is not moved under
normal operating conditions.
N/A
21.8
Aluminium wires
No aluminium wires
P
Содержание JTS-315LA
Страница 2: ......
Страница 3: ...8 JPW s CE declaration of conformity with latest directives and EN standards...
Страница 4: ...9 CE certificates...
Страница 5: ......
Страница 6: ......
Страница 17: ...Appendix A A1 A2 A3 A4...
Страница 19: ...Parts Breakdown for JTS 315LA Table Saw...
Страница 30: ......
Страница 41: ......
Страница 124: ...Circular Saw Bench...