Chapter 7
DS0 VF Test Commands
Description of VF test commands
70
CT-650 Command-Line Reference Guide
Release 9.4
Talk/Listen
Instructs the RTU to route an incoming signal from a phone to the
circuit under test.
Syntax
Talk/Listen <
>
Remarks
– Use this command to communicate with a person at the other end
of the circuit.
– Each end of the circuit can have any device with a speaker or
microphone, such as a telephone or another test device.
– The parameter
digroup_side
is required for drop and insert
testing.
–
Talk/Listen
is only available after a executing a
Measure
and
Listen
.
–
Measure
,
Dial_Out
, or
Loopback
determines the
Talk/
Listen
receiver side (TAD Testing only).
–
Measure
,
Dial_Out
, or
Loopback
reverts a
Talk/Listen
back to a
Listen
.
Example
Below is a sequence of commands that establishes talk/listen.
1
Monitor
or
DI_Monitor
a VF channel.
2
Listen
to channel.
3
VF_Split
or
VF_DI_Split
the circuit.
4
Use
Talk/Listen
.
TLHangup
Hangs up a
Listen
or
Talk/Listen
session.
Syntax
TLHangup <
>
Remark
The parameter
digroup_side
is required for drop and insert testing.
Содержание CT-650
Страница 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 2: ......
Страница 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 4: ......
Страница 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Страница 104: ...Chapter 7 DS0 VF Test Commands Description of VF test commands 78 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 108: ...Chapter 8 Batch Files Unavailable commands for batch files 82 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 198: ...Appendix A Test Results Definitions Loopback status information 172 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Страница 247: ......