Chapter 4
DS1 Test Commands
Considerations for SLC-96 testing
50
CT-650 Command-Line Reference Guide
Release 9.4
Example
The following command initiates a DS1 monitor on the 3ECS1 DCS,
digroup number 111. The test name is test234, and the log file name
is
maint1
. The test uses automatic framing and continuous test dura-
tion.
Monitor 3ecs1 111 test234 maint1 auto continuous
UF_Split
Establishes an intrusive split with the selected digroup.
Syntax
UF_Split <
<
> <
Remark
The commands
Information CRS
and
Information TAPS
screens provide cross-connect and system resource information. For
an example of cross-connect information, see
.
Example
The following command initiates a universal FAD split on the unifad
system, digroup 44, using ESF framing format. The test name is test3,
and the log file name is
log3
.
UF_Split unifad 44 esf test3 log3
Yellow_Alarm
Turns off or on the insertion of yellow alarms to the specified digroup
side.
Syntax
Yellow_Alarm <
> Off|On
Considerations for SLC-96 testing
Below are special considerations for testing SLC-96 systems.
– SLC-96 is supported on the DTU card only.
– The DTU autoframes to SLC-96 DS1 circuits.
Содержание CT-650
Страница 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 2: ......
Страница 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 4: ......
Страница 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Страница 104: ...Chapter 7 DS0 VF Test Commands Description of VF test commands 78 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 108: ...Chapter 8 Batch Files Unavailable commands for batch files 82 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 198: ...Appendix A Test Results Definitions Loopback status information 172 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Страница 247: ......