VISCAM 1000 Systems
44
Appendix B
Basic Settings
Operation Modes:
Operation mode: UDP – specify the operation mode of the serial channel.
Destination IP address 1: Enter IP addresses into the Begin and End fields to cover the range of camera
addresses serviced by this TLS-301 or enter the broadcast address into the Begin field (example:
10.0.0.255) to cover the entire subnet.
Local Listen Port: 4001
Data Packing:
Packing length: 0
Delimiter 1: 0D –check Enable
Delimiter 2: 00
Delimiter Process: Do Nothing
Force transmit: 30
Figure 44.