SP-5000M-PMCL / SP-5000C-PMCL
- 32 -
Note: a: Actual operating value b: Calculation value
Table 20. Continuous Trigger / Horizontal timing 1X4
–
1Y (2/2)
Camera Settings
T
a
p
Ge
o
m
e
tr
y
Cam
e
ra
L
ink
P
ixel Cloc
k
AOI
Binning
1Line
Total
Clock
Horizontal
Frequency
Horizontal
Period
Width
Offset
X
Height
Offset
Y
Horiz
ontal
Verti
cal
[Unit: Clock]
[Unit: kHz]
[Unit: us]
1X4
-1Y
82.3
MHz
2560
0
2048
0
1
(Off)
1
(Off)
a
643 to 646
127.972 to 127.378
7.814 to 7.851
b
644.57
127.632
7.835
1280
0
2048
0
2
(On)
1
(Off)
a
643 to 646
127.972 to 127.378
7.814 to 7.851
b
644.57
127.632
7.835
2560
0
1024
0
1
(Off)
2
(On)
a
643 to 646
127.972 to 127.378
7.814 to 7.851
b
644.57
127.632
7.835
1280
0
1024
0
2
(On)
2
(On)
a
643 to 646
127.972 to 127.378
7.814 to 7.851
b
644.57
127.632
7.835
75.4
MHz
2560
0
2048
0
1
(Off)
1
(Off)
a
643 to 646
117.308 to 116.861
8.525 to 8.557
b
644.29
117.073
8.542
1280
0
2048
0
2
(On)
1
(Off)
a
643 to 646
117.308 to 116.861
8.525 to 8.557
b
644.29
117.073
8.542
2560
0
1024
0
1
(Off)
2
(On)
a
643 to 646
117.308 to 116.861
8.525 to 8.557
b
644.29
117.073
8.542
1280
0
1024
0
2
(On)
2
(On)
a
643 to 646
117.308 to 116.861
8.525 to 8.557
b
644.29
117.073
8.542
61.7
MHz
2560
0
2048
0
1
(Off)
1
(Off)
a
644 to 647
95.829 to 95.385
10.435 to 10.484
b
645.43
95.617
10.458
1280
0
2048
0
2
(On)
1
(Off)
a
644 to 647
95.829 to 95.385
10.435 to 10.484
b
645.43
95.617
10.458
2560
0
1024
0
1
(Off)
2
(On)
a
644 to 647
95.829 to 95.385
10.435 to 10.484
b
645.43
95.617
10.458
1280
0
1024
0
2
(On)
2
(On)
a
644 to 647
95.829 to 95.385
10.435 to 10.484
b
645.43
95.617
10.458