(2) Multi ROI Width
The setting range and Step number are the same as the normal ROI setting in which
[Width] plus [Offset X] should be equal to [Width Max]. In Multi ROI operation, the
maximum offset value in index 1 to index 8 is the object in this calculation.
(3) Multi ROI Index Selector
:
Index 1 to 8 can be selected. [Height], [Offset X], and [Offset Y] of the selected Multi ROI
Index are displayed and can be set.
(4) Multi ROI Offset X
:
Offset X can be set for each ROI area of Multi ROI Index 1 to 8.
The restriction for setting Step and other factors are the same as the normal ROI setting.
As described before, in Multi ROI operation, Multi ROI Width is a common width setting for
Multi ROI Index 1 to 8.
(5) Multi ROI Height
:
Height can be set for each ROI area of Multi ROI Index 1 to 8.
The restriction for setting Step and other factors are the same as the normal ROI setting.
(6) Multi ROI Offset Y
:
Offset Y can be set for each ROI area of Multi ROI Index 1 to 8.
The restriction for setting Step and other factors is the same as the normal ROI setting.
The sum of Multi ROI Height values of index 1 to 8 should be less than Height Max.