SP-5000M-PMCL / SP-5000C-PMCL
- 58 -
Fig. 28 Sequence trigger timing
7.10 Multi ROI function
This function divides one frame image into a maximum of 8 images vertically and reads out all
areas in one frame. In this function, width is the same for all 8 images.
Multi ROI setting
Video Sending Mode: Set to Multi ROI
Table 45 Multi ROI Index table default values
7.10.1 Multi ROI setting parameters
(1) Multi ROI Index Max
:
Setting value = 1
~
8
Maximum 8 ROI settings are possible in a frame. Set Index 1 through 8 in Multi ROI Index
table as an application requires.
Multi ROI Index Max
1
Multi ROI Width
2560
Multi ROI
Index Selector
Multi ROI
Height
Offset
X
Y
- Index 1
1
0
0
- Index 2
1
0
0
- Index 3
1
0
0
- Index 4
1
0
0
- Index 5
1
0
0
- Index 6
1
0
0
- Index 7
1
0
0
- Index 8
1
0
0
Video Send Mode
Frame Start
Trigger In
“Normal”
“Trigger Sequence”
Sequence Index
Can be changed
Sequence Index
Cannot be changed
Sequence
Index
Execute from
Index 0
Sequence Index
Can be changed
“Normal”
Sequence
Index
Pointer
&
Repetition
Count
Clear
Sequence
Index Execute
From Index 0
“Trigger Sequence”
Sequence Index
Cannot be changed
Frame Active
Out
Sequence Index
Performing
Sequence Index
Stop
Sequence Index
Performing
Sequence Index
Stop
Sequence Reset
Command
“Execute”
Sequen
ce
Index
Execute
from
Index 0