2.4.5 Acquisition Control
Name
Interface
Acce
ss
Short
ASCII
Values
MIN
MAX
DEFA
ULT
Description
FrameStartTrig
Mode
I
Enumera
tion
R/W TM
Off/On
0
1
0
TM=[Param.]<CR><LF>
TM?<CR><LF>
TrigSoftware
I
Comman
d
(R)/
W
STRG
0
-
-
-
STRG=0<CR><LF>
FrameStartTrig
Source
I
Enumera
tion
R/W TI
0: Low
1: High
2: SoftTrigger
8: PulseGenerator0
9: PulseGenerator1
10: PulseGenerator2
11: PulseGenerator3
12: TTL_In1
13: CL_CC1_In
14: Nand0
15: Nand1
16: TTL_In2(Option)
17: LVDS_In(Option)
0
17
0
TI=[Param.]<CR><LF>
TI?<CR><LF>
FrameStartTrig
Activation
I
Enumera
tion
R/W TA
0: RisingEdge
1: FallingEdge
2: LevelHigh
3: LevelLow
0
3
0
TA=[Param.]<CR><LF>
TA?<CR><LF>
FrameStartTrig
Over Lap
I
Enumera
tion
R/W TO
0: Off / 1: ReadOut
0
1
0
TO=[Param.]<CR><LF>
TO?<CR><LF>
ExposureMode
I
Enumera
tion
R/W EM
0: Off
1: Timed
2: TriggerWidth
0
2
0
EM=[Param.]<CR><LF>
EM?<CR><LF>
ExposureTimeR
aw
I Integer
R/W PE
Min
~
Max[us]
10
80000
00
18000
PE=[Param.]<CR><LF>
PE?<CR><LF>
ExposureAuto
I
Enumera
tion
R/W ASC
0: Off
2: Once
1: Continuous
0
2
2
ASC=[Param.]<CR><LF>