SP-5000M-PMCL / SP-5000C-PMCL
- 81 -
2.4.6 Digital I/O Control
Name
Interface
Acces
s
Short
ASCII
Values
MI
N
M
AX
DE
FA
UL
T
Description
LineInverter_Line1
I Boolean R/W
LI0
False/True
0
1
0
LI0=[Param.]<CR><LF>
LI0?<CR><LF>
LineInverter_Line8
I Boolean R/W
LI1
False/True
0
1
0
LI1=[Param.]<CR><LF>
LI1?<CR><LF>
LineInverter_Line9
I Boolean R/W
LI2
False/True
0
1
0
LI2=[Param.]<CR><LF>
LI2?<CR><LF>
LineInverter_Nand0In
1
I Boolean R/W
ND0IN
V1
False/True
0
1
0
ND0INV1=[Param.]<CR><LF>
ND0INV1?<CR><LF>
LineInverter_Nand0In
2
I Boolean R/W
ND0IN
V2
False/True
0
1
0
ND0INV2=[Param.]<CR><LF>
ND0INV2?<CR><LF>
LineInverter_Nand1In
1
I Boolean R/W
ND1IN
V1
False/True
0
1
0
ND1INV1=[Param.]<CR><LF>
ND0INV1?<CR><LF>
LineInverter_Nand1In
2
I Boolean R/W
ND1IN
V2
False/True
0
1
0
ND1INV2=[Param.]<CR><LF>
ND0INV2?<CR><LF>
LineSource_Line1
I
Enume
ration
R/W
LS0
0: Low
1: High
3: Frame
TriggerWait
4: Frame
Active
5: Exposure
Active
6: Fval
7: Lval
8: Pulse
Generator0
9: Pulse
Generator1
10: Pulse
Generator2
11: Pulse
Generator3
12: TTL_In
13:
CL_CC1_In
14: Nand0
15: Nand1
16: TTL_In2
(Option)
17: LVDS_In
(Option)
0
17 0
LS0=[Param.]<CR><LF>
LS0?<CR><LF>
For 12pin TTL out
LineSource_Line8
I
Enume
ration
R/W
LS1
Same as for
Line1
0
17 0
LS1=[Param.]<CR><LF>
LS1?<CR><LF>
For Option TTL out
LineSource_Line9
I
Enume
ration
R/W
LS2
Same as for
Line1
0
17 0
LS2=[Param.]<CR><LF>
LS2?<CR><LF>
For Option TTL out
LineSource_Nand0In1
I
Enume
ration
R/W
ND0IN1
Same as for
Line1
0
17 0
ND0IN1=[Param.]<CR><LF>
ND0IN1?<CR><LF>
LineSource_Nand0In2
I
Enume
ration
R/W
ND0IN2
Same as for
Line1
0
17 0
ND0IN2=[Param.]<CR><LF>
ND0IN2?<CR><LF>
LineSource_Nand1In1
I
Enume
ration
R/W
ND1IN1
Same as for
Line1
0
17 0
ND1IN1=[Param.]<CR><LF>
ND1IN1?<CR><LF>