OM-2245 / Operation and Maintenance Manual
ITW GSE 4400 / 400 Hz. Generator Set
March 15, 2015
Chapter 1-3
Page 4
1.
Press and hold
Ɣ
for approximately 5 seconds.
2.
Use navigation keys (
ŻźŸŹ
) to highlight the setup icon.
Press
Ɣ
to select.
3.
Use navigation keys (
źŸ
) to highlight the EF Interlock line. Press
Ɣ
to select.
4.
Set EF interlock to bypass.
5.
Press
Ɣ
to accept the change.
6.
Use navigation keys (
Ż
or
Ź
) to go back to the default screen. Display will automatically
return to the default screen after a period of inactivity.
f)
Discontinue Power Delivery with Unit Shutdown
i)
Normal conditions
a
Push the Output ON/OFF push-button next to the lit green LED indicator to open that output
load contactor. The indicating light next to that button will go OFF, indicating that the load
contactor has opened and power is no longer being delivered to the aircraft. Once all of the
contactors are opened, the engine will remain at rated speed and the generator will remain
active. If idle is enabled, the generator will deactivate and the engine will return to idle after a
short delay.
b
Push the engine Start/Stop push-button switch once to begin the automatic shutdown
sequence to shut off the engine after approximately 5 minutes.
ii)
Emergency conditions
(1) Depress the “
EMERGENCY STOP BUTTON
” located on the front of the unit to the right of
the control panel. When pushed, this button shuts the generator set off. Pull the button back
out to reset it before restarting the generator set.
CAUTION
Do not use the “
EMERGENCY STOP BUTTON
” button as a normal shutdown device.
Damage to the engine turbo charger may result without proper cooling time. Use the
Engine ON/OFF push-button for all normal engine shutdowns.
g) Display –
i)
The display will automatically dim if the engine has been off for at least 10 minutes. Pushing any
button will return the display to full brightness. Once the display dims, if no button is pushed in the
next couple of minutes, the display will turn off.
ii)
If the display is off, and the battery disconnect switch is closed, press the Engine pushbutton to
return the display to full brightness.
Содержание 4400
Страница 2: ......
Страница 48: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 11 ...
Страница 49: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 12 ...
Страница 50: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 13 ...
Страница 60: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 23 ...
Страница 61: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 24 ...
Страница 112: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set This page is intentionally left blank ...
Страница 204: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set This page is intentionally left blank ...
Страница 211: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set This page is intentionally left blank ...
Страница 212: ......
Страница 213: ......