OM-2245 / Operation and Maintenance Manual
ITW GSE 4400 / 400 Hz. Generator Set
March 15, 2015
Appendix A
Page 4
A-3-1 Standard wiring diagram
For service, maintenance and test purposes, the interlock system can be by-passed via the display setup. To
ensure personnel health and safety, the converter automatically returns into normal mode once it receives a
28 VDC voltage at terminal F2. (e.g. when the plug is connected to an aircraft.)
*This option requires a “split
-
F” co
nnector, which is typically a special order from most aircraft manufactures.
Note!
The 90% switch is by-passed by connecting te & 3
A.4
Operator’s Instruction
The 28 VDC ARU is operated by means of the Display / Keyboard Interface.
Please refer to Chapter 1-3 section 3 (ARU Operators Instructions).
A.5 Operating
the
unit
x
To adapt the 28 VDC output power to different types of aircraft, it is possible to set a maximum DC
current level in steps of 200 Amp (400 A unit) and 300 A (600 A unit). Depending on the rating of the
GPU:
400 A rating e.g. 200, 400, 600, 800, 1000, 1200, 1400, 1600 Amp
600 A rating e.g. 300, 600, 900, 1200, 1500, 1800, 2100, 2400 Amp
To ensure hassle-free starting of the aircraft engine, the current limit function is delayed 0.7 seconds.
Press
“Right arrow”
to increase
current limit.
Press
“Left arrow”
to decrease current
limit.
Содержание 4400
Страница 2: ......
Страница 48: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 11 ...
Страница 49: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 12 ...
Страница 50: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 13 ...
Страница 60: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 23 ...
Страница 61: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set March 15 2015 Chapter 1 3 Page 24 ...
Страница 112: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set This page is intentionally left blank ...
Страница 204: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set This page is intentionally left blank ...
Страница 211: ...OM 2245 Operation and Maintenance Manual ITW GSE 4400 400 Hz Generator Set This page is intentionally left blank ...
Страница 212: ......
Страница 213: ......