ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
Page 5-7
Revised 1/05
Service Functions,
cont.
To Set Temperature Scale
The Temperature Scale may be set to display temperature either in degrees Celsius or Fahrenheit.
Press the Service icon four times to set the Temperature
Scale.
Scroll to choose between Celsius (”C”) or Fahrenheit
(”F”) as indicated by the Temperature Scale LED. When
programming is complete, wait a few seconds and the
controller will return to the ASU’s actual temperature.
x 4
or
To Set Ready Delay
When the system is ready (all temperature zones are within tolerance), a ready delay may be pro-
grammed to delay the system’s ready output signal.
Press the Service icon five times to set a Ready Delay.
You will see “d--1” to indicate you are in Ready Delay
programming mode.
Press the Tank icon to display the Ready Delay.
To change a Ready Delay, scroll up or down to the
desired length (in minutes) of delay.
0 = Default, no delay
99 minutes = maximum length of delay
When programming is complete, wait a few seconds and
the controller will return to the ASU’s actual temperature.