ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
Page 7-3
Revised 1/05
Overtemp Thermostat
The overtemp thermostat is a safety back-up. If the hopper temperature exceeds 232
°
C (450
°
F), the
thermostat causes a circuit breaker to open and power to the hopper and all hoses and heads will be
cut off. The overtemp thermostat re-sets when the hopper temperature falls below 204
°
C (400
°
F).
To re-set, turn the main power switch OFF, then ON again.
Location of Printed Circuit Boards and Overtemp Thermostat
Overtemp Thermostat
Control PC Board
PCB Board
Sensor
Heater
Overtemp Thermostat