ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
Page 5-5
Revised 1/05
Service Functions
, cont.
Standby Programming
“Standby” is a temperature value by which all temperature zones will lower when Standby mode
is activated. For example, if your temperature setpoints are all 300 degrees, and you program a
100 degree Standby, then the Standby temperature of all zones will be 200 degrees. Similarly, if
your temperature zones setpoints vary, and you program a 100 degrees Standby, each zone’s
Standby temperature will be 100 degrees lower than its setpoint.
Press Service icon to enter Service Functions.
You will see either “S--1” (standby is On) or “S--0”
(standby is Off).
Press the Tank icon to activate/ de-activate Standby.
If desired, you may set the Standby temperature by
scrolling up or down to desired temperature.
When programming is complete, wait a few seconds
and the controller will return to the ASU’s actual
temperature.
or
Note: When Standby is active, the display will alternate between the ASU’s actual temperature
and S--1.