ITW Dynatec c. 2004
DYNAMINI ASU Manual #20-25
Page 6-1
Revised 1/05
Chapter 6
PREVENTIVE MAINTENANCE
Note: Re-read Chapter 1 “Safety Precautions” before performing any maintenance procedures. All
maintenance procedures must be performed by qualified, trained technicians.
General Cleaning
Follow the manufacturer’s directions when using industrial cleaners on the enclosure.
Preventive Maintenence
Output Filter
During the first weeks of operation, the output filter must be replaced monthly.
To replace the output filter:
1. Follow instructions “Purging the Filter
Manifold of Adhesive and Pressure”, page 6-2.
2. Unscrew and remove the filter nut
(15.8 mm or 5/8” nut).
3. With pliers, pull the filter basket out.
4. Replace the o-ring on the filter nut. Apply
o-ring lubricant (PN N07588) to the new
o-ring.
5. Replace the filter basket.
6. Apply anti-seize to the threads of the filter
nut and re-install. Tighten the filter nut until
it is seated firmly, taking care not to cut the
o-ring.
Hose Fittings & Fasteners
Periodically check all hose fittings and screws for tightness.
Filter Nut
Filter Basket
O-ring
Output Filter
Manifold
Purge Screw
Purge Drain (on underside)