Guidelines for compliance
Compliance is fulfilled only when you operate the unit within its intended use. Do not change the condi-
tions of the service without the approval of an ITT representative. When you install or maintain explosion
proof products, always comply with the directive and applicable standards (for example, IEC/EN
60079-14).
1.
Monitoring the pump frame and liquid end temperature.
2.
Maintaining proper bearing lubrication.
3.
Ensuring that the pump is operated in the intended hydraulic range.
The ATEX conformance is only applicable when the pump unit is operated within its intended use. Oper-
ating, installing or maintaining the pump unit in any way that is not covered in the Instruction, Operation,
and Maintenance manual (IOM) can cause serious personal injury or damage to the equipment. This in-
cludes any modification to the equipment or use of parts not provided by ITT Goulds Pumps. If there is
any question regarding the intended use of the equipment, please contact an ITT Goulds representative
before proceeding.
https://www.gouldspumps.com/en-US/Tools-and-Resources/Literature/
or from your local ITT Goulds Pumps Sales representative.
All pumping unit (pump, seal, coupling, motor and pump accessories) certified for use in an ATEX classi-
fied environment, are identified by an ATEX tag secured to the pump or the baseplate on which it is
mounted. A typical tag would look like this:
Figure 1: Typical ATEX pump nameplate
Table 2: Temperature class definitions
Code Maximum permissible
pumpage temperature in °C | °F
Minimum permissible pumpage temperature in °C | °F
T1
450 | 842
372 | 700
T2
300 | 572
277 | 530
T3
200 | 392
177 | 350
T4
135 | 275
113 | 235
T5
100 | 212
Option not available
T6
85 | 185
Option not available
The code classification marked on the equipment must be in accordance with the specified area where
the equipment will be installed. If it is not, do not operate the equipment and contact your ITT Goulds
Pumps sales representative before proceeding.
The CE and the Ex designate the ATEX compliance. The code below reads as follows:
II - Group – Non Mining Equipment
II = Group 2
2 = Category 2
G/D = Gas and Dust present
1.5 ATEX Considerations and Intended Use
10
3500XD Installation, Operation and Maintenance Instructions
Содержание Goulds Pumps 3500XD
Страница 1: ...Installation Operation and Maintenance Instructions 3500XD ...
Страница 2: ......