6 Maintenance
6.1 Lubrication
NOTICE:
Operation of the unit without proper lubrication will cause bearing failure, and pump seizure.
NOTICE:
Pumps are shipped without oil. Oil lubricated bearings must be lubricated at the job site.
Oil lubricated bearings must be lubricated at the job site. Remove fill plug and add oil until level is at the
center of the sight glass. Replace fill plug.
Change the oil after 2000 hours for new bearings, thereafter every 2000 operating hours or 3 months
(whichever comes first). Change more often if oil becomes contaminated with dirt or water.
A high quality turbine oil with rust and oxidation inhibitors should be used. For the majority of operational
conditions, bearing temperatures will run between 60°C (140°F) and 82°C (180°F). In this range, an oil of
ISO viscosity grade 68 at 40°C (105°F) is recommended. If bearing temperatures exceed 82°C (180°F),
use of ISO viscosity grade 100 is recommended.
Acceptable Oils
Exxon Teresstic EP 68
Chevron GTS Oil 68
Mobil Mobil DTE 26 300 SSU @ 38°C (100°F)
Gulf Gulf Harmony 68
Phillips Magnus Oil Grade 315
Phillips MM motor oil SAE 20-20W
Phillips HDS motor oil SAE 20-20W
Table 5: Lubricating oil requirements
Bearing Temperature
below 82°C
(180°F)
Bearing Tempera-
ture above 82°C
(180°F)
ISO Grade
VG 68
VG 100
Approx. SSU at 38°C
(100°F)
300
470
DIN 51517
C68
C100
Kinematic viscosity at
40°C (105°F
mm2/sec
68
100