7.
Tighten drive collar set screws on cartridge mechanical seal. Loosen and remove centering tabs.
8.
Replace auxiliary piping.
Follow procedures outlined in Preparation for start-up. NOTE: Pay particular attention to instruc-
tions concerning alignment and lubrication.
WARNING:
Before installation or disassembly of the coupling guard is performed, the driver must be de-
energized, the driver controller/starter put in a locked out position and a caution tag placed at
the controller/starter indicating the disconnect. Replace coupling guard before resuming normal
operation of the pump or serious physical injury may occur. Goulds Pumps, Inc. assumes no
liability for avoiding the practice.
WARNING:
Before beginning any alignment procedure, make sure driver power is locked out. Failure to
lock out driver power may result in serious physical injury.
NOTICE:
Operation of the unit without proper lubrication will cause bearing failure, and pump seizure.
CAUTION:
Use of couplings which have excessive weight can cause shaft failure and lead to physical in-
jury. Consult pump manufacturer for recommended weight limits for couplings should the origi-
nally supplied coupling be changed.
6.6 How to order
When ordering parts call 1-800-446-8537 or your local Goulds Representative
6.7 Emergency service
Emergency parts service is available 24 hours/day, 365 days/year.
Call 1-800-446-8537