WARNING
Noise:
Sound pressure levels may exceed 80 dbA in operating process plants. Clear
visual warnings or other indicators should be available to those entering an
area with unsafe noise levels. Personnel should wear appropriate hearing pro-
tection when working on or around any equipment, including pumps. Consider
limiting personnel’s exposure time to noise or, where possible, enclosing
equipment to reduce noise. Local law may provide specific guidance regard-
ing exposure of personnel to noise and when noise exposure reduction is re-
quired.
WARNING
Temperature:
Equipment and piping surfaces may exceed 130ºF (54ºC) in operating proc-
ess plants. Clear visual warnings or other indicators should alert personnel to
surfaces that may reach a potentially unsafe temperature. Do not touch hot
surfaces. Allow pumps operating at a high temperature to cool sufficiently be-
fore performing maintenance. If touching a hot surface cannot be avoided,
personnel should wear appropriate gloves, clothing, and other protective gear
as necessary. Local law may provide specific guidance regarding exposure of
personnel to unsafe temperatures.
1.5
ATEX Considerations and Intended Use
Special care must be taken in potentially explosive environments to ensure that the equipment is proper-
ly maintained. This includes but is not limited to:
Product and product handling requirements
These are the product and product handling requirements for Ex-approved products in potentially explo-
sive atmospheres:
•
Only use the product in accordance with the approved motor data.
•
The Ex-approved product must never run dry during normal operation. Dry running during service
and inspection is only permitted outside the classified area.
•
Before you start work on the product, make sure that the product and the control panel are isolated
from the power supply and the control circuit, so they cannot be energized.
•
Do not open the product while it is energized or in an explosive gas atmosphere.
•
Make sure that thermal contacts are connected to a protection circuit according to the approval
classification of the product, and that they are in use.
•
Intrinsically safe circuits are normally required for the automatic level-control system by the level
regulator if mounted in zone 0.
•
Do not modify the equipment without approval from an authorized ITT representative.
•
Only use parts that are provided by an authorized ITT representative.
Description of ATEX
The ATEX directives are a specification enforced in Europe for electrical and non-electrical equipment
installed in Europe. ATEX deals with the control of potentially explosive atmospheres and the standards
of equipment and protective systems used within these atmospheres. The relevance of the ATEX re-
quirements is not limited to Europe. You can apply these guidelines to equipment installed in any poten-
tially explosive atmosphere.
1.5 ATEX Considerations and Intended Use