3 Installation
3.1 Site / foundation
A pump should be located near the supply of liquid and have adequate space for operation, mainte-
nance, and inspection.
Baseplate mounted pumps are normally grouted on a concrete foundation, which has been poured on a
solid footing. The foundation must be able to absorb any vibration and to form a permanent, rigid support
for the pumping unit.
The location and size of the foundation bolts are shown on the outline assembly drawing, provided with
the pump data package.
Foundation bolts commonly used are sleeve type (Fig. 6) and J Type (Fig. 7). Both designs permit move-
ment for final bolt adjustment.
1
2
3
4
5
6
1.
Baseplate
2.
Shims
3.
Foundation
4.
Sleeve
5.
Dam
6.
Bolt
Figure 6: Sleeve type bolts
1
3
2
4
5
1.
Baseplate
2.
Shims
3.
Foundation
4.
Dam
5.
Bolt
Figure 7: J type bolts
3 Installation
16
3500XD Installation, Operation and Maintenance Instructions
Содержание Goulds Pumps 3500XD
Страница 1: ...Installation Operation and Maintenance Instructions 3500XD ...