2.5 Install suction piping
1.
General - properly installed suction piping is of extreme importance for trouble-free centrifugal pump
operation.
a) The suction pipe should be as large or larger than the pump suction.
b) lncreasers, if used, should be eccentric and preferably at the pump suction flange, sloping side
down.
c)
A centrifugal pump should never be throttled on the suction side for capacity adjustment.
d) When more than one pump is operating from the same source of supply, separate suction
lines, if possible, should be used. If not possible for separate lines, piping arrangement as
shown in
2.5 Install suction piping
3316 Installation, Operation and Maintenance Instructions
13
Содержание GOULDS PUMPS 3316
Страница 1: ...Installation Operation and Maintenance Instructions 3316 ...
Страница 2: ......
Страница 18: ...Figure 6 2 5 Install suction piping 16 3316 Installation Operation and Maintenance Instructions ...
Страница 41: ...Figure 20 7 10 Overhaul of pump 3316 Installation Operation and Maintenance Instructions 39 ...
Страница 44: ...Figure 22 Left hand pump 7 11 Reassembly of pump 42 3316 Installation Operation and Maintenance Instructions ...