Group S
Group M
Group L
1-1/2x2
-9
2x3-9G
2x3-9
2-3-1
1
3x4-1
1
G
3x4-1
1
H
4x6-1
1
HG
4x6-1
1
6x8-17
6-10-17
Max liquid temp without cool-
ing or quenching
250°F
Max liquid temp with quench-
ing gland and bearing cool-
ing
350°F
†Max suction pressure is 240 PSIG
*Gland quenching recommended on hot water above 212°F
7.9 Pressure & Temperature Capability
Code for Pressure - Temperature Chart
Group
Curve
Casing
Material
Acceptable minimum standard ANSI mating flanges and
fittings
Suction
Discharge
M
A
316 SST
300 PSI flat face 316 SST
300 PSI flat face 316 SST
B
Bronze
300 PSI flat face bronze
C
C1
250 PSI flat face cast iron
S
D
316 SST
300 PSI flat face 316 SST
E
Bronze
300 PSI flat face bronze
F
C1
250 PSI flat face cast iron
L
I
316 SST
300 PSI flat face 316 SST
300 PSI flat face 316 SST
J
Bronze
300 PSI flat face bronze
300 PSI flat face bronze
K
C1
250 PSI flat face cast iron
250 PSI flat face cast iron
7.9 Pressure & Temperature Capability
3316 Installation, Operation and Maintenance Instructions
37
Содержание GOULDS PUMPS 3316
Страница 1: ...Installation Operation and Maintenance Instructions 3316 ...
Страница 2: ......
Страница 18: ...Figure 6 2 5 Install suction piping 16 3316 Installation Operation and Maintenance Instructions ...
Страница 41: ...Figure 20 7 10 Overhaul of pump 3316 Installation Operation and Maintenance Instructions 39 ...
Страница 44: ...Figure 22 Left hand pump 7 11 Reassembly of pump 42 3316 Installation Operation and Maintenance Instructions ...