Figure 7:
2.6 Piping - discharge
1.
A gate valve and a check valve should be installed in the discharge line. The check valve should
be located between the gate valve and pump to permit inspection of the check valve. The gate
valve is required for priming, regulation of flow capacity and for inspection and maintenance of
the pump. See
.
2.
lncreasers, if used in discharge line, should be placed between the check valve and the pump.
2.7 Connection of piping
Connect suction and discharge piping. Rotate the pump shaft by hand several complete revolutions to be
sure that there is no binding and that all parts are free. Recheck alignment as described in Section Align-
ment - initial. If the connection of the piping causes unit to be out of alignment, correct piping to relieve
strain on the pump.
2.8 Check rotation
The direction of rotation is marked on the pump casing. Make sure that driver rotates in the same direc-
tion. On electric motors, jog starting switch to be sure wiring is connected for correct rotation. Be sure
that coupling is disconnected.
2.9 Connection of coupling
Connect coupling, following instructions for the particular make of coupling furnished. This data is sup-
plied separately, giving complete instructions for connection, lubrication, alignment and maintenance.
NOTICE:
Pumps and drivers are bedplated so that when coupling faces are positioned in accordance
with the manufacturer's recommended gap, there is an overhang of approximately 1/8" from
shaft ends to coupling hub faces.
2.6 Piping - discharge
3316 Installation, Operation and Maintenance Instructions
17
Содержание GOULDS PUMPS 3316
Страница 1: ...Installation Operation and Maintenance Instructions 3316 ...
Страница 2: ......
Страница 18: ...Figure 6 2 5 Install suction piping 16 3316 Installation Operation and Maintenance Instructions ...
Страница 41: ...Figure 20 7 10 Overhaul of pump 3316 Installation Operation and Maintenance Instructions 39 ...
Страница 44: ...Figure 22 Left hand pump 7 11 Reassembly of pump 42 3316 Installation Operation and Maintenance Instructions ...