Table 2: Temperature class definitions
Code
Maximum permissible surface tem-
perature in °C | °F
Maximum permissible liquid tempera-
ture in °C | °F
T1
440 | 824
372 | 700
T2
290 | 554
267 | 513
T3
195 | 383
172 | 342
T4
130 | 266
107 | 225
T5
Option not available
Option not available
T6
Option not available
Option not available
The code classification marked on the equipment should be in accordance with the specified area where
the equipment will be installed. If it is not, please contact your ITT/Goulds representative before proceed-
ing.
* Maximum liquid temperature may be limited by the pump model and order specific options.
Temperature class definitions on page 16
is for the purpose of determining T'x' code for ATEX applica-
tions with liquid temperatures exceeding 107ºC | 225ºF.
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure the pump driver and all other auxiliary components meet the required area classifica-
tion at the site. If they are not compatible, do not operate the equipment and contact an ITT
representative before proceeding.
3.2 Nameplate information
16
Model 3296 EZMAG Installation, Operation, and Maintenance Manual