Y X
Figure 18: Top view of an incorrect horizontal alignment
5.
Repeat the previous steps until the permitted reading value is achieved.
4.3.5.5 Perform complete alignment for a vertical correction
Before you start this procedure, make sure that the dial indicators are properly attached for measure-
ment.
A unit is in complete alignment when both the angular indicator (A) and the parallel indicator (P) do not
vary by more than 0.05 mm | 0.002 in. as measured at four points 90° apart.
1.
Set the angular and parallel dial indicators to zero at the top-center position (12 o’clock) of the driver
coupling half (Y).
2.
Rotate the indicators to the bottom-center position (6 o’clock).
3.
Record the indicator readings.
4.
Make corrections according to the separate instructions for angular and parallel alignment until you
obtain the permitted reading values.
When the procedure is complete, both the angular and parallel alignment must meet the permitted toler-
ances.
4.3.5.6 Perform complete alignment for a horizontal correction
Before you start this procedure, make sure that the dial indicators are properly attached for measure-
ment.
A unit is in complete alignment when both the angular indicator (A) and the parallel indicator (P) do not
vary by more than 0.05 mm | 0.002 in. as measured at four points 90° apart.
1.
Set the angular and parallel dial indicators to zero at the left side of the driver coupling half (Y), 90°
from the top-center position (9 o’clock).
2.
Rotate the indicators through the top-center position to the right side, 180° from the start position
(3 o’clock).
3.
Record the indicator readings.
4.
Make corrections according to the separate instructions for angular and parallel alignment until you
obtain the permitted reading values.
When the procedure is complete, both the angular and parallel alignment must meet the permitted toler-
ances.
4.4 Grout the baseplate
Required equipment:
•
Cleaners: Do not use an oil-based cleaner because the grout will not bond to it. See the instructions
provided by the grout manufacturer.
•
Grout: Non-shrink grout is recommended.
1.
Clean all the areas of the baseplate that will come into contact with the grout.
2.
Build a dam around the foundation.
3.
Thoroughly wet the foundation that will come into contact with the grout.
4.4 Grout the baseplate