Figure 36: Exploded view of the spring assembly
6.4.16 Disassemble the spring-mounted baseplate (second generation)
WARNING:
Springs can store energy that can launch parts at a high velocity. Before you perform any
tasks, make sure that all springs are positively locked against free expansion.
NOTICE:
The spring-mounted baseplate is designed only to support piping loads from thermal expan-
sion. Ensure that the suction and discharge piping are supported individually. Failure to do so
may result in equipment damage.
1.
Remove the pump and motor from the baseplate in order to remove the springs.
2.
Make sure all the springs are positively locked against free expansion.
3.
Raise the baseplate and support it so the mounting brackets for the spring assemblies are approxi-
mately 16 in. (406 mm) above the foundation/floor.
4.
Remove the upper hex jam nuts from each stud.
5.
Carefully unthread the upper nuts, and allow the springs to expand slowly until the springs are loose
between the followers.
Leave the upper hex nuts on the studs.
6.
Unthread and remove the studs from the bearing pads.
7.
Unthread and remove the lower hex jam nuts from the studs.
6.4 Disassembly
94
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...
Страница 155: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 153 ...