164 360P 356E
100
357A
6.4.7 Remove the suction sideplate
WARNING:
Sideplates are heavy. Use the proper support to avoid personal injury.
This procedure only applies to models that have an open impeller or a Shearpeller
TM
.
1.
Remove the hex nuts (357A) from the sideplate studs (356E).
2.
Remove the sideplate (176) from the casing (100) using a pry bar in the provided slot.
6.4 Disassembly