5.14 Deactivate the i-ALERT
®
2 Equipment Health Monitor
NOTICE:
Always deactivate the health monitor when the pump is going to be shut down for an extended
period of time. Failure to do so will result in reduced battery life.
5.15 Reset the i-ALERT
®
2 Health Monitor
To deactivate or reset the i-ALERT
®
2 monitor, please refer to the i-ALERT
®
Always reset the health monitor when the pump is started after maintenance, system change, or being
shut down for an extended period of time. Failure to do so may result in false baseline levels that could
cause the health monitor to alert in error.
1.
Touch a magnet to the health monitor over the ITT logo to turn the power on.
The health monitor begins to establish a new baseline vibration level.
Figure 35: i-ALERT
®
2 Equipment Health monitor
5.16 Make the final alignment of the pump and driver
WARNING:
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
5.14 Deactivate the i-ALERT®2 Equipment Health Monitor
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
69