Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
•
Risk of serious personal injury. Applying heat to impellers, propellers, or their retaining
devices can cause trapped liquid to rapidly expand and result in a violent explosion. This
manual clearly identifies accepted methods for disassembling units. These methods must
be adhered to. Never apply heat to aid in their removal unless explicitly stated in this
manual.
•
Handling heavy equipment poses a crush hazard. Use caution during handling and wear
appropriate Personal Protective Equipment (PPE, such as steel-toed shoes, gloves, etc.)
at all times.
•
Precautions must be taken to prevent physical injury. The pump may handle hazardous
and/or toxic fluids. Proper personal protective equipment should be worn. Pumpage must
be handled and disposed of in conformance with applicable environmental regulations.
•
Risk of serious physical injury or death from rapid depressurization. Ensure pump is iso-
lated from system and pressure is relieved before disassembling pump, removing plugs,
opening vent or drain valves, or disconnecting piping.
•
Risk of serious personal injury from exposure to hazardous or toxic liquids. A small
amount of liquid will be present in certain areas like the seal chamber upon disassembly.
CAUTION:
•
Avoid injury. Worn pump components can have sharp edges. Wear appropriate gloves
while handling these parts.
6.4.2 Tools required
In order to disassemble the pump, you need these tools:
•
Allen wrenches
•
Cleaning agents and solvents
•
Chisel
•
Dial indicators
•
Feeler gauges
•
Hoist and strap
•
Induction heater
•
Pry bars
•
Sockets
•
Soft face hammer
•
Spanner wrench
•
Torque wrench
•
Wrenches
•
Lifting eyebolt (dependent on pump / motor size)
6.4.3 Drain the pump
CAUTION:
•
Risk of physical injury. Allow all system and pump components to cool before handling.
6.4 Disassembly
78
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...
Страница 155: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 153 ...